Extension board · Power output
Switch one small DC load, such as a fan or a solenoid, from a 3.3 V signal on the three-pin header or Gadgeteer IN. The load has its own power supply. One type-Y host socket can provide seven independent control signals for a chain of seven boards.
Prototype design · not built or tested yet
All three boards switch one DC load. The voltages and currents are design targets; none of the boards has been tested on hardware.
| Small MOSFET basic | Small MOSFET advanced | Large MOSFET | |
|---|---|---|---|
| Specifications | |||
| Load supply | 12 V DC nominal | 5 to 24 V DC | 5 to 24 V DC |
| Load current, design target | 1 A | 4 A | 12.5 A |
| Load connector | Screw terminal | Screw terminal | XT30 |
| Control connector | Three-pin header and Gadgeteer IN / CHAIN | Three-pin header and Gadgeteer IN / CHAIN | Three-pin header and Gadgeteer IN / CHAIN |
| Features | |||
| Works from a 3.3 V control signal | |||
| Optically isolated control | |||
| Output stays off with the control cable unplugged | |||
| Diode for inductive loads (fans, solenoids) | |||
| Boards per Gadgeteer port | Up to seven | Up to seven | Up to seven |
| Can feed a small load from the controller | |||
| Reversed-supply protection | |||
| Electronic current limit | |||
| Switches off when the supply voltage is out of range | |||
| Soft start | |||
| Light for output on | |||
| Lights for faults | |||
| M3 mounting holes | |||
| Cable-tie holes | |||
| Item | Prototype design target |
|---|---|
| Output | One low-side DC switch with a flyback diode |
| Control | One active-high 3.3 V logic signal, with a hardware pull-down |
| Field supply | 12 V nominal, externally supplied and current limited |
| Continuous load | 1 A initial qualification target |
| Indicators | Green POWER and amber ON, each with a separate disable link |
| Mounting | Ungrounded M3 holes on a 10 mm grid and load-cable tie holes |
The routed prototype measures 41 × 32 mm in KiCad. The supply and load figures are design targets. Electrical ratings and fabrication suitability remain unverified.
With power off, connect a correctly polarized, current-limited external supply to EXT+ and GND. Connect the load positive to LOAD+ and its negative to LOAD−. LOAD+ is connected directly to EXT+ and remains live while external power is present. The board switches LOAD− to ground. Ground is shared with the controller for signaling.
Connect only a verified type-Y host socket or the previous board’s CHAIN connector to IN, using a keyed straight-through cable. Keep the load return on the external wiring. Both Gadgeteer supply rails pass to the next socket and have no connection to the load or either indicator.
For direct control through 3-PIN IN, power down and cut the factory bridge between pads 1 and 2 of SELECT. Bridge pads 2 and 3 to select the three-pin input. Close one bridge only. Connect controller ground and an active-high 3.3 V command. The middle contact is unused.
| 3-PIN IN contact | Function |
|---|---|
| 1 | Controller ground, shared with field supply ground |
| 2 | Unconnected |
| 3 | Active-high 3.3 V command |
| IN pin | Function | CHAIN pin |
|---|---|---|
| 1 | Controller 3.3 V pass-through | 1 |
| 2 | Controller 5 V pass-through | 2 |
| 3 | This board’s load command | — |
| 4 | Next board’s load command | 3 |
| 5 | Remaining command | 4 |
| 6 | Remaining command | 5 |
| 7 | Remaining command | 6 |
| 8 | Remaining command | 7 |
| 9 | Remaining command | 8 |
| 10 | Shared signal ground | 10 |
CHAIN pin 9 is unconnected. Each forwarded command has an individual normally closed solder link. The connectors are directional.
With Gadgeteer selected, the first board uses the signal on host pin 3. Each board shifts the remaining commands by one position on its CHAIN connector. In a full chain the seventh board uses the signal that started on host pin 9. Removing a board and reconnecting its neighbors shifts the channel assignment of every board after it. Power down before changing the chain. Use one host and confirm its socket pinout and pin assignments before connecting hardware.
POWER lights when external power is present. ON lights when the switched return is pulled low with external power present. It can light with the load unplugged. Both disable links are closed by default.
The flyback diode provides a recirculation path for an inductive load at turn-off. The basic circuit relies on correct supply polarity and an external current-limited source. See the small MOSFET advanced board for onboard supply protection and fault indicators.