Provide an optically isolated, single-channel AC mains switch targeting 240 VAC and 16 A; the proposed 48 V/30 A DC variant is a separate future board.
Baseline documentation snapshot: 2026-10-11, before the requested connector/protection/usability revision program. New revision features require their own reviewed source and qualification evidence.
This page documents an unqualified engineering study, not a released or tested product. Saved CAD, renders and automated checks do not establish a safe assembly, compatible cable, firmware support or a usable current rating.
Board-specific qualification limits: v10 native/ordinaryassembly0;triac/fuse/PE/insulation/offleakage/heatsink/thermal-link/procurement/physical unqualified.
Power off before connecting or changing jumpers. Verify pin 1, signal direction, supply voltage and ground at both ends of every cable. A mechanically fitting connector is not proof of electrical compatibility. If a host pin mapping or current allocation remains unresolved in the design record, do not connect the board until it is resolved.
The following are specification requirements or study assumptions; they are not measured operating ratings. A newer selected-revision note takes precedence over historical draft options.
The design describes the following protection intent. Check the selected schematic and remaining qualification gates before relying on it:
Mandatory input fuse, thermal cutoff/monitoring, touch-safe enclosure, surge suppression, strain relief, earth treatment, and standards-derived creepage/clearance.
See current review. Retain isolated AC optotriac/triac,thermalcutoff and sensing. Existing exact V1 Molex J1 and conditional R3 1k10%0603 reuse retained,no successor. Current selected v10; retained native/stock/physical qualification limits remain explicit.
Use the configuration and firmware contract for the exact selected revision. Do not copy another module’s socket assignments or assume that an unused pin is available. First-article work must verify source selection, reset/unplug behavior, cable orientation and the actual load or sensor interface before normal operation.
The following are requirements for the next design iterations; this page does not claim they are already fitted:
Documentation route: smoothieware.org/extensions/single-channel-solid-state-relay-output.
The 2026-10-11 upgrade program has saved additional candidates v11, v12, v13. These studies preserve the historical design described above. Their connector, LED, mechanical and protection changes are revision-specific and remain unqualified.
See the per-board changes, failures and remaining work and mandatory family specification. Use the source hash and native check for the exact candidate being reviewed; do not infer hardware ratings from a rendered population.
The three additional revisions are v11, v12, v13. They are engineering studies; saved CAD and renders do not release the hardware. The latest candidate is described below. Older baseline notes above remain historical.
d439c4d7e0fdf97b99623ca78ceba03ec8038c7a9a99d9c09925c38c09ad6a45.Applicable protection, current-path, thermal, pinout, cable access and physical tests remain open wherever the linked board record has not verified them. A zero native-error count does not close those gates.
Protected source v14; current PCB SHA-256 a9a3ad2b99f623ff2511fb501cf348dc9666d1da85b4c49fdac78559a48cda32. Fresh checks: zero enabled PCB errors/opens/parity and ERC errors; 1 PCB warnings. Electrical geometry, project rules and 80 historical files unchanged. Verified 23 model entries, 17 exports and 6 current population views, all inspected. Full documentation URL readable. Mains safety/current/creepage/thermal qualification open; existing isolation lands and warning text preserved Inherited native warnings and enabled-rule exclusions remain explicit Physical/thermal/current/connector-fit qualification open No priced or area savings established by annotation candidate.