Historical six-axis interface board

This large V2 interface combines six external STEP/DIR channels, shared enable, ABC min/max endstops, four small-FET PWM outputs, UART0, an ordinary E-stop input and a 40-contact harness connector. It requires four distinct Gadgeteer inputs. It does not add six power stages or guarantee a machine has six supported kinematic axes.

Documented revision and original host

This guide documents the historical Ccecil source snapshot, pinned by the local Smoothieboard2 parent, rather than a modern replacement board. The exact upstream revision identifies the retained design. A repository commit is not an assembly revision or evidence of current production. The source targets the Smoothieboard V2/Gadgeteer era. That intended generation does not prove compatibility with every later V2 Prime board, cable or firmware build.

Interfaces, power and limitations

J3 carries XYZ commands and J4 ABC commands; J2 carries ABC min/max states; J1 carries E_STOP,UART TX/RX and PWM1_1–4. J7–J12 are per-axis1 5 V, 2 STEP, 3 DIR, 4 shared ENABLE, 5 ground. J18–J23 are ABC endstop connectors. J13 is the complete40-contact harness whose exact map is listed below. JP19 selects default 5 V or an external source at J24 for VS; changing it can change PWM connector power. Several signals are level shifted/buffered; the 40-pin cable is not an ordinary parallel-port cable.

Raw and buffered endstop contacts are different nodes

For A-min, J18.3 feeds U3.1 through R18 (1 kΩ). R9 (10 kΩ) pulls that raw input up through JP11 and JP5; the source-default JP5 bridge 1–2 selects 5 V. J18.2 is ground. The same raw input appears at J13.11 (A_MIN_IN), so J13.11 must not be treated as a 3.3 V host input merely because it carries an endstop signal.

The buffered output is J2.7 (Amin), connected to U3.2. U3 is the source’s 3.3 V-powered 74LCX07 open-drain buffer; an appropriate output-side pull-up and receiver limits must be established separately. J2.7 and J13.11 are not interchangeable. Confirm the fitted part, bridge continuity and both sides’ voltage/current limits before allocating either to Prime. This distinction does not establish a complete endstop installation or motor-control recipe.

Board-reference diagram

The overview and numbered contact sheets use the canonical abstract for the documented source revision. Pills identify native contacts, and dashed leaders locate components rather than electrical wires. Rear selectors are source-position projections, not a claim about visible or fitted solder bridges. Do not connect a Prime cable until supply selection, raw versus buffered signals, receiver limits and physical mating are resolved. These reference drawings do not establish a complete powered installation.

Six-axis breakout — historical source reference
Six-axis breakout Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Six-axis breakout — historical source reference
Six-axis breakout
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Six-axis breakout — historical source reference
Connectors and harness contacts
Host header J1 / 1 — historical source reference
Host header J1 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Host header J1 / 1 — historical source reference
Host header J1 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Host header J1 / 1 — historical source reference
Host header J1 / 2 — historical source reference
Host header J1 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Host header J1 / 2 — historical source reference
Host header J1 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Host header J1 / 2 — historical source reference
Driver controls J10 / 1 — historical source reference
Driver controls J10 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Driver controls J10 / 1 — historical source reference
Driver controls J10 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Driver controls J10 / 1 — historical source reference
Driver controls J11 / 1 — historical source reference
Driver controls J11 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Driver controls J11 / 1 — historical source reference
Driver controls J11 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Driver controls J11 / 1 — historical source reference
Driver controls J12 / 1 — historical source reference
Driver controls J12 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Driver controls J12 / 1 — historical source reference
Driver controls J12 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Driver controls J12 / 1 — historical source reference
Full header J13 / 1 — historical source reference
Full header J13 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Full header J13 / 1 — historical source reference
Full header J13 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Full header J13 / 1 — historical source reference
Full header J13 / 2 — historical source reference
Full header J13 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Full header J13 / 2 — historical source reference
Full header J13 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Full header J13 / 2 — historical source reference
Full header J13 / 3 — historical source reference
Full header J13 / 3 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Full header J13 / 3 — historical source reference
Full header J13 / 3
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Full header J13 / 3 — historical source reference
Full header J13 / 4 — historical source reference
Full header J13 / 4 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Full header J13 / 4 — historical source reference
Full header J13 / 4
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Full header J13 / 4 — historical source reference
Full header J13 / 5 — historical source reference
Full header J13 / 5 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Full header J13 / 5 — historical source reference
Full header J13 / 5
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Full header J13 / 5 — historical source reference
Full header J13 / 6 — historical source reference
Full header J13 / 6 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Full header J13 / 6 — historical source reference
Full header J13 / 6
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Full header J13 / 6 — historical source reference
Full header J13 / 7 — historical source reference
Full header J13 / 7 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Full header J13 / 7 — historical source reference
Full header J13 / 7
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Full header J13 / 7 — historical source reference
Full header J13 / 8 — historical source reference
Full header J13 / 8 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Full header J13 / 8 — historical source reference
Full header J13 / 8
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Full header J13 / 8 — historical source reference
FET output J14 / 1 — historical source reference
FET output J14 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

FET output J14 / 1 — historical source reference
FET output J14 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

FET output J14 / 1 — historical source reference
FET output J15 / 1 — historical source reference
FET output J15 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

FET output J15 / 1 — historical source reference
FET output J15 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

FET output J15 / 1 — historical source reference
FET output J16 / 1 — historical source reference
FET output J16 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

FET output J16 / 1 — historical source reference
FET output J16 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

FET output J16 / 1 — historical source reference
FET output J17 / 1 — historical source reference
FET output J17 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

FET output J17 / 1 — historical source reference
FET output J17 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

FET output J17 / 1 — historical source reference
Endstop input J18 / 1 — historical source reference
Endstop input J18 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Endstop input J18 / 1 — historical source reference
Endstop input J18 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Endstop input J18 / 1 — historical source reference
Endstop input J19 / 1 — historical source reference
Endstop input J19 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Endstop input J19 / 1 — historical source reference
Endstop input J19 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Endstop input J19 / 1 — historical source reference
Host header J2 / 1 — historical source reference
Host header J2 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Host header J2 / 1 — historical source reference
Host header J2 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Host header J2 / 1 — historical source reference
Host header J2 / 2 — historical source reference
Host header J2 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Host header J2 / 2 — historical source reference
Host header J2 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Host header J2 / 2 — historical source reference
Endstop input J20 / 1 — historical source reference
Endstop input J20 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Endstop input J20 / 1 — historical source reference
Endstop input J20 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Endstop input J20 / 1 — historical source reference
Endstop input J21 / 1 — historical source reference
Endstop input J21 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Endstop input J21 / 1 — historical source reference
Endstop input J21 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Endstop input J21 / 1 — historical source reference
Endstop input J22 / 1 — historical source reference
Endstop input J22 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Endstop input J22 / 1 — historical source reference
Endstop input J22 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Endstop input J22 / 1 — historical source reference
Endstop input J23 / 1 — historical source reference
Endstop input J23 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Endstop input J23 / 1 — historical source reference
Endstop input J23 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Endstop input J23 / 1 — historical source reference
VS access J24 / 1 — historical source reference
VS access J24 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

VS access J24 / 1 — historical source reference
VS access J24 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

VS access J24 / 1 — historical source reference
Host header J3 / 1 — historical source reference
Host header J3 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Host header J3 / 1 — historical source reference
Host header J3 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Host header J3 / 1 — historical source reference
Host header J3 / 2 — historical source reference
Host header J3 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Host header J3 / 2 — historical source reference
Host header J3 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Host header J3 / 2 — historical source reference
Host header J4 / 1 — historical source reference
Host header J4 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Host header J4 / 1 — historical source reference
Host header J4 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Host header J4 / 1 — historical source reference
Host header J4 / 2 — historical source reference
Host header J4 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Host header J4 / 2 — historical source reference
Host header J4 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Host header J4 / 2 — historical source reference
UART0 row J5 / 1 — historical source reference
UART0 row J5 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

UART0 row J5 / 1 — historical source reference
UART0 row J5 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

UART0 row J5 / 1 — historical source reference
E-stop row J6 / 1 — historical source reference
E-stop row J6 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

E-stop row J6 / 1 — historical source reference
E-stop row J6 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

E-stop row J6 / 1 — historical source reference
Driver controls J7 / 1 — historical source reference
Driver controls J7 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Driver controls J7 / 1 — historical source reference
Driver controls J7 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Driver controls J7 / 1 — historical source reference
Driver controls J8 / 1 — historical source reference
Driver controls J8 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Driver controls J8 / 1 — historical source reference
Driver controls J8 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Driver controls J8 / 1 — historical source reference
Driver controls J9 / 1 — historical source reference
Driver controls J9 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Driver controls J9 / 1 — historical source reference
Driver controls J9 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Driver controls J9 / 1 — historical source reference
Rear selector contacts
Rear selector JP1 / 1 — historical source reference
Rear selector JP1 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP1 / 1 — historical source reference
Rear selector JP1 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP1 / 1 — historical source reference
Rear selector JP10 / 1 — historical source reference
Rear selector JP10 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP10 / 1 — historical source reference
Rear selector JP10 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP10 / 1 — historical source reference
Rear selector JP11 / 1 — historical source reference
Rear selector JP11 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP11 / 1 — historical source reference
Rear selector JP11 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP11 / 1 — historical source reference
Rear selector JP12 / 1 — historical source reference
Rear selector JP12 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP12 / 1 — historical source reference
Rear selector JP12 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP12 / 1 — historical source reference
Rear selector JP13 / 1 — historical source reference
Rear selector JP13 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP13 / 1 — historical source reference
Rear selector JP13 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP13 / 1 — historical source reference
Rear selector JP14 / 1 — historical source reference
Rear selector JP14 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP14 / 1 — historical source reference
Rear selector JP14 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP14 / 1 — historical source reference
Rear selector JP15 / 1 — historical source reference
Rear selector JP15 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP15 / 1 — historical source reference
Rear selector JP15 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP15 / 1 — historical source reference
Rear selector JP16 / 1 — historical source reference
Rear selector JP16 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP16 / 1 — historical source reference
Rear selector JP16 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP16 / 1 — historical source reference
Rear selector JP17 / 1 — historical source reference
Rear selector JP17 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP17 / 1 — historical source reference
Rear selector JP17 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP17 / 1 — historical source reference
Rear selector JP18 / 1 — historical source reference
Rear selector JP18 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP18 / 1 — historical source reference
Rear selector JP18 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP18 / 1 — historical source reference
Rear selector JP19 / 1 — historical source reference
Rear selector JP19 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP19 / 1 — historical source reference
Rear selector JP19 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP19 / 1 — historical source reference
Rear selector JP2 / 1 — historical source reference
Rear selector JP2 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP2 / 1 — historical source reference
Rear selector JP2 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP2 / 1 — historical source reference
Rear selector JP3 / 1 — historical source reference
Rear selector JP3 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP3 / 1 — historical source reference
Rear selector JP3 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP3 / 1 — historical source reference
Rear selector JP4 / 1 — historical source reference
Rear selector JP4 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP4 / 1 — historical source reference
Rear selector JP4 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP4 / 1 — historical source reference
Rear selector JP5 / 1 — historical source reference
Rear selector JP5 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP5 / 1 — historical source reference
Rear selector JP5 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP5 / 1 — historical source reference
Rear selector JP6 / 1 — historical source reference
Rear selector JP6 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP6 / 1 — historical source reference
Rear selector JP6 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP6 / 1 — historical source reference
Rear selector JP7 / 1 — historical source reference
Rear selector JP7 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP7 / 1 — historical source reference
Rear selector JP7 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP7 / 1 — historical source reference
Rear selector JP8 / 1 — historical source reference
Rear selector JP8 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP8 / 1 — historical source reference
Rear selector JP8 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP8 / 1 — historical source reference
Rear selector JP9 / 1 — historical source reference
Rear selector JP9 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP9 / 1 — historical source reference
Rear selector JP9 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP9 / 1 — historical source reference
Logic, transistor, resistor and mounting contacts
Passive C1 / 1 — historical source reference
Passive C1 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive C1 / 1 — historical source reference
Passive C1 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive C1 / 1 — historical source reference
Passive C2 / 1 — historical source reference
Passive C2 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive C2 / 1 — historical source reference
Passive C2 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive C2 / 1 — historical source reference
Passive C3 / 1 — historical source reference
Passive C3 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive C3 / 1 — historical source reference
Passive C3 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive C3 / 1 — historical source reference
Passive C4 / 1 — historical source reference
Passive C4 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive C4 / 1 — historical source reference
Passive C4 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive C4 / 1 — historical source reference
Passive C5 / 1 — historical source reference
Passive C5 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive C5 / 1 — historical source reference
Passive C5 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive C5 / 1 — historical source reference
Passive C6 / 1 — historical source reference
Passive C6 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive C6 / 1 — historical source reference
Passive C6 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive C6 / 1 — historical source reference
Passive C7 / 1 — historical source reference
Passive C7 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive C7 / 1 — historical source reference
Passive C7 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive C7 / 1 — historical source reference
Passive C8 / 1 — historical source reference
Passive C8 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive C8 / 1 — historical source reference
Passive C8 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive C8 / 1 — historical source reference
Mounting H1 / 1 — historical source reference
Mounting H1 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Mounting H1 / 1 — historical source reference
Mounting H1 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Mounting H1 / 1 — historical source reference
Mounting H2 / 1 — historical source reference
Mounting H2 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Mounting H2 / 1 — historical source reference
Mounting H2 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Mounting H2 / 1 — historical source reference
Mounting H3 / 1 — historical source reference
Mounting H3 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Mounting H3 / 1 — historical source reference
Mounting H3 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Mounting H3 / 1 — historical source reference
Mounting H4 / 1 — historical source reference
Mounting H4 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Mounting H4 / 1 — historical source reference
Mounting H4 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Mounting H4 / 1 — historical source reference
MOSFET Q1 / 1 — historical source reference
MOSFET Q1 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q1 / 1 — historical source reference
MOSFET Q1 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q1 / 1 — historical source reference
MOSFET Q1 / 2 — historical source reference
MOSFET Q1 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q1 / 2 — historical source reference
MOSFET Q1 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q1 / 2 — historical source reference
MOSFET Q10 / 1 — historical source reference
MOSFET Q10 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q10 / 1 — historical source reference
MOSFET Q10 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q10 / 1 — historical source reference
MOSFET Q11 / 1 — historical source reference
MOSFET Q11 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q11 / 1 — historical source reference
MOSFET Q11 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q11 / 1 — historical source reference
MOSFET Q12 / 1 — historical source reference
MOSFET Q12 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q12 / 1 — historical source reference
MOSFET Q12 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q12 / 1 — historical source reference
MOSFET Q13 / 1 — historical source reference
MOSFET Q13 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q13 / 1 — historical source reference
MOSFET Q13 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q13 / 1 — historical source reference
MOSFET Q2 / 1 — historical source reference
MOSFET Q2 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q2 / 1 — historical source reference
MOSFET Q2 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q2 / 1 — historical source reference
MOSFET Q2 / 2 — historical source reference
MOSFET Q2 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q2 / 2 — historical source reference
MOSFET Q2 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q2 / 2 — historical source reference
MOSFET Q3 / 1 — historical source reference
MOSFET Q3 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q3 / 1 — historical source reference
MOSFET Q3 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q3 / 1 — historical source reference
MOSFET Q3 / 2 — historical source reference
MOSFET Q3 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q3 / 2 — historical source reference
MOSFET Q3 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q3 / 2 — historical source reference
MOSFET Q4 / 1 — historical source reference
MOSFET Q4 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q4 / 1 — historical source reference
MOSFET Q4 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q4 / 1 — historical source reference
MOSFET Q4 / 2 — historical source reference
MOSFET Q4 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q4 / 2 — historical source reference
MOSFET Q4 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q4 / 2 — historical source reference
MOSFET Q5 / 1 — historical source reference
MOSFET Q5 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q5 / 1 — historical source reference
MOSFET Q5 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q5 / 1 — historical source reference
MOSFET Q5 / 2 — historical source reference
MOSFET Q5 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q5 / 2 — historical source reference
MOSFET Q5 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q5 / 2 — historical source reference
MOSFET Q6 / 1 — historical source reference
MOSFET Q6 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q6 / 1 — historical source reference
MOSFET Q6 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q6 / 1 — historical source reference
MOSFET Q6 / 2 — historical source reference
MOSFET Q6 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q6 / 2 — historical source reference
MOSFET Q6 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q6 / 2 — historical source reference
MOSFET Q7 / 1 — historical source reference
MOSFET Q7 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q7 / 1 — historical source reference
MOSFET Q7 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q7 / 1 — historical source reference
MOSFET Q7 / 2 — historical source reference
MOSFET Q7 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q7 / 2 — historical source reference
MOSFET Q7 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q7 / 2 — historical source reference
MOSFET Q8 / 1 — historical source reference
MOSFET Q8 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q8 / 1 — historical source reference
MOSFET Q8 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q8 / 1 — historical source reference
MOSFET Q8 / 2 — historical source reference
MOSFET Q8 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q8 / 2 — historical source reference
MOSFET Q8 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q8 / 2 — historical source reference
MOSFET Q9 / 1 — historical source reference
MOSFET Q9 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q9 / 1 — historical source reference
MOSFET Q9 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q9 / 1 — historical source reference
MOSFET Q9 / 2 — historical source reference
MOSFET Q9 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

MOSFET Q9 / 2 — historical source reference
MOSFET Q9 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

MOSFET Q9 / 2 — historical source reference
Passive R1 / 1 — historical source reference
Passive R1 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R1 / 1 — historical source reference
Passive R1 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R1 / 1 — historical source reference
Passive R10 / 1 — historical source reference
Passive R10 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R10 / 1 — historical source reference
Passive R10 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R10 / 1 — historical source reference
Passive R11 / 1 — historical source reference
Passive R11 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R11 / 1 — historical source reference
Passive R11 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R11 / 1 — historical source reference
Passive R12 / 1 — historical source reference
Passive R12 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R12 / 1 — historical source reference
Passive R12 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R12 / 1 — historical source reference
Passive R13 / 1 — historical source reference
Passive R13 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R13 / 1 — historical source reference
Passive R13 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R13 / 1 — historical source reference
Passive R14 / 1 — historical source reference
Passive R14 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R14 / 1 — historical source reference
Passive R14 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R14 / 1 — historical source reference
Passive R15 / 1 — historical source reference
Passive R15 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R15 / 1 — historical source reference
Passive R15 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R15 / 1 — historical source reference
Passive R16 / 1 — historical source reference
Passive R16 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R16 / 1 — historical source reference
Passive R16 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R16 / 1 — historical source reference
Passive R17 / 1 — historical source reference
Passive R17 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R17 / 1 — historical source reference
Passive R17 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R17 / 1 — historical source reference
Passive R18 / 1 — historical source reference
Passive R18 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R18 / 1 — historical source reference
Passive R18 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R18 / 1 — historical source reference
Passive R19 / 1 — historical source reference
Passive R19 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R19 / 1 — historical source reference
Passive R19 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R19 / 1 — historical source reference
Passive R2 / 1 — historical source reference
Passive R2 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R2 / 1 — historical source reference
Passive R2 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R2 / 1 — historical source reference
Passive R20 / 1 — historical source reference
Passive R20 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R20 / 1 — historical source reference
Passive R20 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R20 / 1 — historical source reference
Passive R21 / 1 — historical source reference
Passive R21 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R21 / 1 — historical source reference
Passive R21 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R21 / 1 — historical source reference
Passive R22 / 1 — historical source reference
Passive R22 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R22 / 1 — historical source reference
Passive R22 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R22 / 1 — historical source reference
Passive R3 / 1 — historical source reference
Passive R3 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R3 / 1 — historical source reference
Passive R3 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R3 / 1 — historical source reference
Passive R4 / 1 — historical source reference
Passive R4 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R4 / 1 — historical source reference
Passive R4 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R4 / 1 — historical source reference
Passive R5 / 1 — historical source reference
Passive R5 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R5 / 1 — historical source reference
Passive R5 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R5 / 1 — historical source reference
Passive R6 / 1 — historical source reference
Passive R6 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R6 / 1 — historical source reference
Passive R6 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R6 / 1 — historical source reference
Passive R7 / 1 — historical source reference
Passive R7 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R7 / 1 — historical source reference
Passive R7 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R7 / 1 — historical source reference
Passive R8 / 1 — historical source reference
Passive R8 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R8 / 1 — historical source reference
Passive R8 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R8 / 1 — historical source reference
Passive R9 / 1 — historical source reference
Passive R9 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Passive R9 / 1 — historical source reference
Passive R9 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Passive R9 / 1 — historical source reference
Resistor array RN1 / 1 — historical source reference
Resistor array RN1 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN1 / 1 — historical source reference
Resistor array RN1 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN1 / 1 — historical source reference
Resistor array RN1 / 2 — historical source reference
Resistor array RN1 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN1 / 2 — historical source reference
Resistor array RN1 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN1 / 2 — historical source reference
Resistor array RN2 / 1 — historical source reference
Resistor array RN2 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN2 / 1 — historical source reference
Resistor array RN2 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN2 / 1 — historical source reference
Resistor array RN2 / 2 — historical source reference
Resistor array RN2 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN2 / 2 — historical source reference
Resistor array RN2 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN2 / 2 — historical source reference
Resistor array RN3 / 1 — historical source reference
Resistor array RN3 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN3 / 1 — historical source reference
Resistor array RN3 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN3 / 1 — historical source reference
Resistor array RN3 / 2 — historical source reference
Resistor array RN3 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN3 / 2 — historical source reference
Resistor array RN3 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN3 / 2 — historical source reference
Resistor array RN4 / 1 — historical source reference
Resistor array RN4 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN4 / 1 — historical source reference
Resistor array RN4 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN4 / 1 — historical source reference
Resistor array RN4 / 2 — historical source reference
Resistor array RN4 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN4 / 2 — historical source reference
Resistor array RN4 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN4 / 2 — historical source reference
Resistor array RN5 / 1 — historical source reference
Resistor array RN5 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN5 / 1 — historical source reference
Resistor array RN5 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN5 / 1 — historical source reference
Resistor array RN5 / 2 — historical source reference
Resistor array RN5 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN5 / 2 — historical source reference
Resistor array RN5 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN5 / 2 — historical source reference
Resistor array RN6 / 1 — historical source reference
Resistor array RN6 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN6 / 1 — historical source reference
Resistor array RN6 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN6 / 1 — historical source reference
Resistor array RN6 / 2 — historical source reference
Resistor array RN6 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN6 / 2 — historical source reference
Resistor array RN6 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN6 / 2 — historical source reference
Resistor array RN7 / 1 — historical source reference
Resistor array RN7 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN7 / 1 — historical source reference
Resistor array RN7 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN7 / 1 — historical source reference
Resistor array RN7 / 2 — historical source reference
Resistor array RN7 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN7 / 2 — historical source reference
Resistor array RN7 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN7 / 2 — historical source reference
Resistor array RN8 / 1 — historical source reference
Resistor array RN8 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN8 / 1 — historical source reference
Resistor array RN8 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN8 / 1 — historical source reference
Resistor array RN8 / 2 — historical source reference
Resistor array RN8 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN8 / 2 — historical source reference
Resistor array RN8 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN8 / 2 — historical source reference
Resistor array RN9 / 1 — historical source reference
Resistor array RN9 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN9 / 1 — historical source reference
Resistor array RN9 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN9 / 1 — historical source reference
Resistor array RN9 / 2 — historical source reference
Resistor array RN9 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Resistor array RN9 / 2 — historical source reference
Resistor array RN9 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Resistor array RN9 / 2 — historical source reference
Source IC U1 / 1 — historical source reference
Source IC U1 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Source IC U1 / 1 — historical source reference
Source IC U1 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Source IC U1 / 1 — historical source reference
Source IC U1 / 2 — historical source reference
Source IC U1 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Source IC U1 / 2 — historical source reference
Source IC U1 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Source IC U1 / 2 — historical source reference
Source IC U2 / 1 — historical source reference
Source IC U2 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Source IC U2 / 1 — historical source reference
Source IC U2 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Source IC U2 / 1 — historical source reference
Source IC U2 / 2 — historical source reference
Source IC U2 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Source IC U2 / 2 — historical source reference
Source IC U2 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Source IC U2 / 2 — historical source reference
Source IC U3 / 1 — historical source reference
Source IC U3 / 1 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Source IC U3 / 1 — historical source reference
Source IC U3 / 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Source IC U3 / 1 — historical source reference
Source IC U3 / 2 — historical source reference
Source IC U3 / 2 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Source IC U3 / 2 — historical source reference
Source IC U3 / 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Source IC U3 / 2 — historical source reference
Source IC U3 / 3 — historical source reference
Source IC U3 / 3 Selected-source contact reference. Rear jumpers are projected source locations; fitted bridges, cable mating, receiver limits and a complete Prime installation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Source IC U3 / 3 — historical source reference
Source IC U3 / 3
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Source IC U3 / 3 — historical source reference

Supplementary logical circuits

These independently drawn circuit sheets explain the selected source connectivity. They do not copy the original board artwork, placement or native files and supplement the populated board-reference diagrams above. Use the contact inventory and all companion sheets together. Physical cable orientation, ratings, installed operation and the full Prime/peripheral wiring remain unverified.

Source: selected original circuit, revision 045d9f7f2947d37b2818cf35008f27b3130f0c2e. No original-artwork redistribution grant has been established.

Six-axis source and use boundaries — logical connections, not physical board layout
Six-axis source and use boundaries Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Six-axis source and use boundaries — logical connections, not physical board layout
Six-axis source and use boundaries
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Six-axis source and use boundaries — logical connections, not physical board layout
J1 exact source contacts — logical connections, not physical board layout
J1 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J1 exact source contacts — logical connections, not physical board layout
J1 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J1 exact source contacts — logical connections, not physical board layout
J1 exact source contacts — logical connections, not physical board layout
J1 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J1 exact source contacts — logical connections, not physical board layout
J1 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J1 exact source contacts — logical connections, not physical board layout
J1 exact source contacts — logical connections, not physical board layout
J1 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J1 exact source contacts — logical connections, not physical board layout
J1 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J1 exact source contacts — logical connections, not physical board layout
J2 exact source contacts — logical connections, not physical board layout
J2 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J2 exact source contacts — logical connections, not physical board layout
J2 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J2 exact source contacts — logical connections, not physical board layout
J2 exact source contacts — logical connections, not physical board layout
J2 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J2 exact source contacts — logical connections, not physical board layout
J2 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J2 exact source contacts — logical connections, not physical board layout
J2 exact source contacts — logical connections, not physical board layout
J2 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J2 exact source contacts — logical connections, not physical board layout
J2 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J2 exact source contacts — logical connections, not physical board layout
J3 exact source contacts — logical connections, not physical board layout
J3 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J3 exact source contacts — logical connections, not physical board layout
J3 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J3 exact source contacts — logical connections, not physical board layout
J3 exact source contacts — logical connections, not physical board layout
J3 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J3 exact source contacts — logical connections, not physical board layout
J3 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J3 exact source contacts — logical connections, not physical board layout
J3 exact source contacts — logical connections, not physical board layout
J3 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J3 exact source contacts — logical connections, not physical board layout
J3 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J3 exact source contacts — logical connections, not physical board layout
J4 exact source contacts — logical connections, not physical board layout
J4 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J4 exact source contacts — logical connections, not physical board layout
J4 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J4 exact source contacts — logical connections, not physical board layout
J4 exact source contacts — logical connections, not physical board layout
J4 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J4 exact source contacts — logical connections, not physical board layout
J4 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J4 exact source contacts — logical connections, not physical board layout
J4 exact source contacts — logical connections, not physical board layout
J4 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J4 exact source contacts — logical connections, not physical board layout
J4 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J4 exact source contacts — logical connections, not physical board layout
J5 exact source contacts — logical connections, not physical board layout
J5 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J5 exact source contacts — logical connections, not physical board layout
J5 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J5 exact source contacts — logical connections, not physical board layout
J6 exact source contacts — logical connections, not physical board layout
J6 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J6 exact source contacts — logical connections, not physical board layout
J6 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J6 exact source contacts — logical connections, not physical board layout
J7 exact source contacts — logical connections, not physical board layout
J7 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J7 exact source contacts — logical connections, not physical board layout
J7 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J7 exact source contacts — logical connections, not physical board layout
J7 exact source contacts — logical connections, not physical board layout
J7 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J7 exact source contacts — logical connections, not physical board layout
J7 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J7 exact source contacts — logical connections, not physical board layout
J8 exact source contacts — logical connections, not physical board layout
J8 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J8 exact source contacts — logical connections, not physical board layout
J8 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J8 exact source contacts — logical connections, not physical board layout
J8 exact source contacts — logical connections, not physical board layout
J8 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J8 exact source contacts — logical connections, not physical board layout
J8 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J8 exact source contacts — logical connections, not physical board layout
J9 exact source contacts — logical connections, not physical board layout
J9 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J9 exact source contacts — logical connections, not physical board layout
J9 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J9 exact source contacts — logical connections, not physical board layout
J9 exact source contacts — logical connections, not physical board layout
J9 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J9 exact source contacts — logical connections, not physical board layout
J9 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J9 exact source contacts — logical connections, not physical board layout
J10 exact source contacts — logical connections, not physical board layout
J10 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J10 exact source contacts — logical connections, not physical board layout
J10 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J10 exact source contacts — logical connections, not physical board layout
J10 exact source contacts — logical connections, not physical board layout
J10 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J10 exact source contacts — logical connections, not physical board layout
J10 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J10 exact source contacts — logical connections, not physical board layout
J11 exact source contacts — logical connections, not physical board layout
J11 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J11 exact source contacts — logical connections, not physical board layout
J11 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J11 exact source contacts — logical connections, not physical board layout
J11 exact source contacts — logical connections, not physical board layout
J11 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J11 exact source contacts — logical connections, not physical board layout
J11 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J11 exact source contacts — logical connections, not physical board layout
J12 exact source contacts — logical connections, not physical board layout
J12 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J12 exact source contacts — logical connections, not physical board layout
J12 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J12 exact source contacts — logical connections, not physical board layout
J12 exact source contacts — logical connections, not physical board layout
J12 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J12 exact source contacts — logical connections, not physical board layout
J12 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J12 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J13 exact source contacts — logical connections, not physical board layout
J13 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J13 exact source contacts — logical connections, not physical board layout
J14 exact source contacts — logical connections, not physical board layout
J14 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J14 exact source contacts — logical connections, not physical board layout
J14 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J14 exact source contacts — logical connections, not physical board layout
J15 exact source contacts — logical connections, not physical board layout
J15 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J15 exact source contacts — logical connections, not physical board layout
J15 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J15 exact source contacts — logical connections, not physical board layout
J16 exact source contacts — logical connections, not physical board layout
J16 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J16 exact source contacts — logical connections, not physical board layout
J16 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J16 exact source contacts — logical connections, not physical board layout
J17 exact source contacts — logical connections, not physical board layout
J17 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J17 exact source contacts — logical connections, not physical board layout
J17 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J17 exact source contacts — logical connections, not physical board layout
J18 exact source contacts — logical connections, not physical board layout
J18 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J18 exact source contacts — logical connections, not physical board layout
J18 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J18 exact source contacts — logical connections, not physical board layout
J19 exact source contacts — logical connections, not physical board layout
J19 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J19 exact source contacts — logical connections, not physical board layout
J19 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J19 exact source contacts — logical connections, not physical board layout
J20 exact source contacts — logical connections, not physical board layout
J20 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J20 exact source contacts — logical connections, not physical board layout
J20 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J20 exact source contacts — logical connections, not physical board layout
J21 exact source contacts — logical connections, not physical board layout
J21 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J21 exact source contacts — logical connections, not physical board layout
J21 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J21 exact source contacts — logical connections, not physical board layout
J22 exact source contacts — logical connections, not physical board layout
J22 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J22 exact source contacts — logical connections, not physical board layout
J22 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J22 exact source contacts — logical connections, not physical board layout
J23 exact source contacts — logical connections, not physical board layout
J23 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J23 exact source contacts — logical connections, not physical board layout
J23 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J23 exact source contacts — logical connections, not physical board layout
J24 exact source contacts — logical connections, not physical board layout
J24 exact source contacts Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

J24 exact source contacts — logical connections, not physical board layout
J24 exact source contacts
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

J24 exact source contacts — logical connections, not physical board layout
JP1 conditional source selection — logical connections, not physical board layout
JP1 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP1 conditional source selection — logical connections, not physical board layout
JP1 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP1 conditional source selection — logical connections, not physical board layout
JP2 conditional source selection — logical connections, not physical board layout
JP2 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP2 conditional source selection — logical connections, not physical board layout
JP2 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP2 conditional source selection — logical connections, not physical board layout
JP3 conditional source selection — logical connections, not physical board layout
JP3 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP3 conditional source selection — logical connections, not physical board layout
JP3 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP3 conditional source selection — logical connections, not physical board layout
JP4 conditional source selection — logical connections, not physical board layout
JP4 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP4 conditional source selection — logical connections, not physical board layout
JP4 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP4 conditional source selection — logical connections, not physical board layout
JP5 conditional source selection — logical connections, not physical board layout
JP5 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP5 conditional source selection — logical connections, not physical board layout
JP5 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP5 conditional source selection — logical connections, not physical board layout
JP6 conditional source selection — logical connections, not physical board layout
JP6 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP6 conditional source selection — logical connections, not physical board layout
JP6 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP6 conditional source selection — logical connections, not physical board layout
JP7 conditional source selection — logical connections, not physical board layout
JP7 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP7 conditional source selection — logical connections, not physical board layout
JP7 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP7 conditional source selection — logical connections, not physical board layout
JP8 conditional source selection — logical connections, not physical board layout
JP8 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP8 conditional source selection — logical connections, not physical board layout
JP8 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP8 conditional source selection — logical connections, not physical board layout
JP9 conditional source selection — logical connections, not physical board layout
JP9 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP9 conditional source selection — logical connections, not physical board layout
JP9 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP9 conditional source selection — logical connections, not physical board layout
JP10 conditional source selection — logical connections, not physical board layout
JP10 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP10 conditional source selection — logical connections, not physical board layout
JP10 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP10 conditional source selection — logical connections, not physical board layout
JP11 conditional source selection — logical connections, not physical board layout
JP11 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP11 conditional source selection — logical connections, not physical board layout
JP11 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP11 conditional source selection — logical connections, not physical board layout
JP12 conditional source selection — logical connections, not physical board layout
JP12 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP12 conditional source selection — logical connections, not physical board layout
JP12 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP12 conditional source selection — logical connections, not physical board layout
JP13 conditional source selection — logical connections, not physical board layout
JP13 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP13 conditional source selection — logical connections, not physical board layout
JP13 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP13 conditional source selection — logical connections, not physical board layout
JP14 conditional source selection — logical connections, not physical board layout
JP14 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP14 conditional source selection — logical connections, not physical board layout
JP14 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP14 conditional source selection — logical connections, not physical board layout
JP15 conditional source selection — logical connections, not physical board layout
JP15 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP15 conditional source selection — logical connections, not physical board layout
JP15 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP15 conditional source selection — logical connections, not physical board layout
JP16 conditional source selection — logical connections, not physical board layout
JP16 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP16 conditional source selection — logical connections, not physical board layout
JP16 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP16 conditional source selection — logical connections, not physical board layout
JP17 conditional source selection — logical connections, not physical board layout
JP17 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP17 conditional source selection — logical connections, not physical board layout
JP17 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP17 conditional source selection — logical connections, not physical board layout
JP18 conditional source selection — logical connections, not physical board layout
JP18 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP18 conditional source selection — logical connections, not physical board layout
JP18 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP18 conditional source selection — logical connections, not physical board layout
JP19 conditional source selection — logical connections, not physical board layout
JP19 conditional source selection Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

JP19 conditional source selection — logical connections, not physical board layout
JP19 conditional source selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

JP19 conditional source selection — logical connections, not physical board layout
X low-side logic — logical connections, not physical board layout
X low-side logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

X low-side logic — logical connections, not physical board layout
X low-side logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

X low-side logic — logical connections, not physical board layout
X driver header — logical connections, not physical board layout
X driver header Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

X driver header — logical connections, not physical board layout
X driver header
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

X driver header — logical connections, not physical board layout
Y low-side logic — logical connections, not physical board layout
Y low-side logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Y low-side logic — logical connections, not physical board layout
Y low-side logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Y low-side logic — logical connections, not physical board layout
Y driver header — logical connections, not physical board layout
Y driver header Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Y driver header — logical connections, not physical board layout
Y driver header
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Y driver header — logical connections, not physical board layout
Z low-side logic — logical connections, not physical board layout
Z low-side logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Z low-side logic — logical connections, not physical board layout
Z low-side logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Z low-side logic — logical connections, not physical board layout
Z driver header — logical connections, not physical board layout
Z driver header Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Z driver header — logical connections, not physical board layout
Z driver header
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Z driver header — logical connections, not physical board layout
A low-side logic — logical connections, not physical board layout
A low-side logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

A low-side logic — logical connections, not physical board layout
A low-side logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

A low-side logic — logical connections, not physical board layout
A driver header — logical connections, not physical board layout
A driver header Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

A driver header — logical connections, not physical board layout
A driver header
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

A driver header — logical connections, not physical board layout
B low-side logic — logical connections, not physical board layout
B low-side logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

B low-side logic — logical connections, not physical board layout
B low-side logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

B low-side logic — logical connections, not physical board layout
B driver header — logical connections, not physical board layout
B driver header Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

B driver header — logical connections, not physical board layout
B driver header
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

B driver header — logical connections, not physical board layout
C low-side logic — logical connections, not physical board layout
C low-side logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

C low-side logic — logical connections, not physical board layout
C low-side logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

C low-side logic — logical connections, not physical board layout
C driver header — logical connections, not physical board layout
C driver header Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

C driver header — logical connections, not physical board layout
C driver header
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

C driver header — logical connections, not physical board layout
Q7 shared logic — logical connections, not physical board layout
Q7 shared logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Q7 shared logic — logical connections, not physical board layout
Q7 shared logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Q7 shared logic — logical connections, not physical board layout
Q8 shared logic — logical connections, not physical board layout
Q8 shared logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Q8 shared logic — logical connections, not physical board layout
Q8 shared logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Q8 shared logic — logical connections, not physical board layout
Q9 shared logic — logical connections, not physical board layout
Q9 shared logic Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Q9 shared logic — logical connections, not physical board layout
Q9 shared logic
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Q9 shared logic — logical connections, not physical board layout
RN1 exact four resistor branches — logical connections, not physical board layout
RN1 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN1 exact four resistor branches — logical connections, not physical board layout
RN1 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN1 exact four resistor branches — logical connections, not physical board layout
RN2 exact four resistor branches — logical connections, not physical board layout
RN2 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN2 exact four resistor branches — logical connections, not physical board layout
RN2 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN2 exact four resistor branches — logical connections, not physical board layout
RN3 exact four resistor branches — logical connections, not physical board layout
RN3 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN3 exact four resistor branches — logical connections, not physical board layout
RN3 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN3 exact four resistor branches — logical connections, not physical board layout
RN4 exact four resistor branches — logical connections, not physical board layout
RN4 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN4 exact four resistor branches — logical connections, not physical board layout
RN4 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN4 exact four resistor branches — logical connections, not physical board layout
RN5 exact four resistor branches — logical connections, not physical board layout
RN5 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN5 exact four resistor branches — logical connections, not physical board layout
RN5 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN5 exact four resistor branches — logical connections, not physical board layout
RN6 exact four resistor branches — logical connections, not physical board layout
RN6 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN6 exact four resistor branches — logical connections, not physical board layout
RN6 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN6 exact four resistor branches — logical connections, not physical board layout
RN7 exact four resistor branches — logical connections, not physical board layout
RN7 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN7 exact four resistor branches — logical connections, not physical board layout
RN7 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN7 exact four resistor branches — logical connections, not physical board layout
RN8 exact four resistor branches — logical connections, not physical board layout
RN8 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN8 exact four resistor branches — logical connections, not physical board layout
RN8 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN8 exact four resistor branches — logical connections, not physical board layout
RN9 exact four resistor branches — logical connections, not physical board layout
RN9 exact four resistor branches Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

RN9 exact four resistor branches — logical connections, not physical board layout
RN9 exact four resistor branches
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

RN9 exact four resistor branches — logical connections, not physical board layout
A min input filter — logical connections, not physical board layout
A min input filter Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

A min input filter — logical connections, not physical board layout
A min input filter
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

A min input filter — logical connections, not physical board layout
A min buffer output — logical connections, not physical board layout
A min buffer output Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

A min buffer output — logical connections, not physical board layout
A min buffer output
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

A min buffer output — logical connections, not physical board layout
A max input filter — logical connections, not physical board layout
A max input filter Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

A max input filter — logical connections, not physical board layout
A max input filter
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

A max input filter — logical connections, not physical board layout
A max buffer output — logical connections, not physical board layout
A max buffer output Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

A max buffer output — logical connections, not physical board layout
A max buffer output
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

A max buffer output — logical connections, not physical board layout
B min input filter — logical connections, not physical board layout
B min input filter Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

B min input filter — logical connections, not physical board layout
B min input filter
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

B min input filter — logical connections, not physical board layout
B min buffer output — logical connections, not physical board layout
B min buffer output Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

B min buffer output — logical connections, not physical board layout
B min buffer output
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

B min buffer output — logical connections, not physical board layout
B max input filter — logical connections, not physical board layout
B max input filter Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

B max input filter — logical connections, not physical board layout
B max input filter
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

B max input filter — logical connections, not physical board layout
B max buffer output — logical connections, not physical board layout
B max buffer output Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

B max buffer output — logical connections, not physical board layout
B max buffer output
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

B max buffer output — logical connections, not physical board layout
C min input filter — logical connections, not physical board layout
C min input filter Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

C min input filter — logical connections, not physical board layout
C min input filter
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

C min input filter — logical connections, not physical board layout
C min buffer output — logical connections, not physical board layout
C min buffer output Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

C min buffer output — logical connections, not physical board layout
C min buffer output
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

C min buffer output — logical connections, not physical board layout
C max input filter — logical connections, not physical board layout
C max input filter Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

C max input filter — logical connections, not physical board layout
C max input filter
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

C max input filter — logical connections, not physical board layout
C max buffer output — logical connections, not physical board layout
C max buffer output Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

C max buffer output — logical connections, not physical board layout
C max buffer output
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

C max buffer output — logical connections, not physical board layout
Q11 output switch — logical connections, not physical board layout
Q11 output switch Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Q11 output switch — logical connections, not physical board layout
Q11 output switch
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Q11 output switch — logical connections, not physical board layout
Q10 output switch — logical connections, not physical board layout
Q10 output switch Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Q10 output switch — logical connections, not physical board layout
Q10 output switch
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Q10 output switch — logical connections, not physical board layout
Q12 output switch — logical connections, not physical board layout
Q12 output switch Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Q12 output switch — logical connections, not physical board layout
Q12 output switch
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Q12 output switch — logical connections, not physical board layout
Q13 output switch — logical connections, not physical board layout
Q13 output switch Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Q13 output switch — logical connections, not physical board layout
Q13 output switch
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Q13 output switch — logical connections, not physical board layout
Shared driver enable — logical connections, not physical board layout
Shared driver enable Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Shared driver enable — logical connections, not physical board layout
Shared driver enable
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Shared driver enable — logical connections, not physical board layout
Shared driver enable — logical connections, not physical board layout
Shared driver enable Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Shared driver enable — logical connections, not physical board layout
Shared driver enable
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Shared driver enable — logical connections, not physical board layout
Stop low-side path — logical connections, not physical board layout
Stop low-side path Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Stop low-side path — logical connections, not physical board layout
Stop low-side path
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Stop low-side path — logical connections, not physical board layout
UART high-side header — logical connections, not physical board layout
UART high-side header Supplementary factual circuit only. Physical mating and a complete Prime installation remain incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

UART high-side header — logical connections, not physical board layout
UART high-side header
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

UART high-side header — logical connections, not physical board layout

Numbered source contacts and controls

These are intended source net memberships, not measured electrical behaviour. Unassigned/unconnected pads must not receive invented connections. Auto-generated net names require schematic interpretation; they are not cable colours. Repeated footprints or pad numbers require geometric identity checks before wiring.

Selected-source contact inventory
Source member Connector/control Source label Contact → source net
6AxisBreakout.kicad_pcb J5 Conn_01x03_Pin 1: GND; 2: RX0; 3: TX0
6AxisBreakout.kicad_pcb J19 Conn_01x03 1: Net-(J19-Pin_1); 2: GND; 3: A_MAX_IN
6AxisBreakout.kicad_pcb J2 Conn_02x05_Odd_Even 1: +3V3; 2: +5V; 3: Cmin; 4: Cmax; 5: Bmin; 6: Bmax; 7: Amin; 8: Amax; 9: Spare1; 10: GND
6AxisBreakout.kicad_pcb J21 Conn_01x03 1: Net-(J21-Pin_1); 2: GND; 3: B_MAX_IN
6AxisBreakout.kicad_pcb J6 Conn_01x03_Pin 1: Net-(J6-Pin_1); 2: GND; 3: Net-(J6-Pin_3)
6AxisBreakout.kicad_pcb J13 Conn_02x20_Odd_Even 1: +3V3; 2: +5V; 3: +3V3; 4: +5V; 5: FET1; 6: FET2; 7: FET3; 8: FET4; 9: TX0; 10: RX0; 11: A_MIN_IN; 12: A_MAX_IN; 13: B_MIN_IN; 14: B_MAX_IN; 15: C_MIN_IN; 16: C_MAX_IN; 17: X_DIR_; 18: X_STP_; 19: Y_DIR_; 20: Y_STP_; 21: Z_DIR_; 22: Z_STP_; 23: A_DIR_; 24: A_STP_; 25: B_DIR_; 26: B_STP_; 27: C_DIR_; 28: C_STP_; 29: EN_; 30: E_STOP_; 31: Spare1; 32: Spare2; 33: GND; 34: GND; 35: GND; 36: GND; 37: GND; 38: GND; 39: GND; 40: GND
6AxisBreakout.kicad_pcb J24 Conn_01x02_Pin 1: GND; 2: Net-(J24-Pin_2)
6AxisBreakout.kicad_pcb J15 Conn_01x03_Pin 1: FET1_; 2: GND; 3: VS
6AxisBreakout.kicad_pcb J10 Conn_01x05_Pin 1: +5V; 2: A_STP_; 3: A_DIR_; 4: EN_; 5: GND
6AxisBreakout.kicad_pcb J7 Conn_01x05_Pin 1: +5V; 2: X_STP_; 3: X_DIR_; 4: EN_; 5: GND
6AxisBreakout.kicad_pcb J3 Conn_02x05_Odd_Even 1: +3V3; 2: +5V; 3: Z_DIR; 4: Z_STP; 5: Y_STP; 6: X_STP; 7: Y_DIR; 8: X_DIR; 9: EN; 10: GND
6AxisBreakout.kicad_pcb J20 Conn_01x03 1: Net-(J20-Pin_1); 2: GND; 3: B_MIN_IN
6AxisBreakout.kicad_pcb J4 Conn_02x05_Odd_Even 1: +3V3; 2: +5V; 3: C_DIR; 4: C_STP; 5: B_STP; 6: A_STP; 7: B_DIR; 8: A_DIR; 9: Spare2; 10: GND
6AxisBreakout.kicad_pcb J9 Conn_01x05_Pin 1: +5V; 2: Z_STP_; 3: Z_DIR_; 4: EN_; 5: GND
6AxisBreakout.kicad_pcb J23 Conn_01x03 1: Net-(J23-Pin_1); 2: GND; 3: C_MAX_IN
6AxisBreakout.kicad_pcb J14 Conn_01x03_Pin 1: FET2_; 2: GND; 3: VS
6AxisBreakout.kicad_pcb J17 Conn_01x03_Pin 1: FET4_; 2: GND; 3: VS
6AxisBreakout.kicad_pcb J18 Conn_01x03 1: Net-(J18-Pin_1); 2: GND; 3: A_MIN_IN
6AxisBreakout.kicad_pcb J16 Conn_01x03_Pin 1: FET3_; 2: GND; 3: VS
6AxisBreakout.kicad_pcb J22 Conn_01x03 1: Net-(J22-Pin_1); 2: GND; 3: C_MIN_IN
6AxisBreakout.kicad_pcb J12 Conn_01x05_Pin 1: +5V; 2: C_STP_; 3: C_DIR_; 4: EN_; 5: GND
6AxisBreakout.kicad_pcb J1 Conn_02x05_Odd_Even 1: +3V3; 2: +5V; 3: E_STOP; 4: TX0; 5: RX0; 6: PWM1_1; 7: PWM1_2; 8: PWM1_3; 9: PWM1_4; 10: GND
6AxisBreakout.kicad_pcb J11 Conn_01x05_Pin 1: +5V; 2: B_STP_; 3: B_DIR_; 4: EN_; 5: GND
6AxisBreakout.kicad_pcb J8 Conn_01x05_Pin 1: +5V; 2: Y_STP_; 3: Y_DIR_; 4: EN_; 5: GND
6AxisBreakout.kicad_pcb JP15 SolderJumper_2_Bridged 1: Net-(J22-Pin_1); 2: Net-(JP15-B)
6AxisBreakout.kicad_pcb JP17 SolderJumper_3_Bridged12 1: +5V; 2: Net-(J6-Pin_1); 3: +3V3
6AxisBreakout.kicad_pcb JP14 SolderJumper_2_Bridged 1: Net-(J21-Pin_1); 2: Net-(JP14-B)
6AxisBreakout.kicad_pcb JP1 SolderJumper_3_Bridged12 1: +5V; 2: Net-(JP1-C); 3: +3V3
6AxisBreakout.kicad_pcb JP12 SolderJumper_2_Bridged 1: Net-(J19-Pin_1); 2: Net-(JP12-B)
6AxisBreakout.kicad_pcb JP16 SolderJumper_2_Bridged 1: Net-(J23-Pin_1); 2: Net-(JP16-B)
6AxisBreakout.kicad_pcb JP2 SolderJumper_3_Bridged12 1: +5V; 2: Net-(JP2-C); 3: +3V3
6AxisBreakout.kicad_pcb JP10 SolderJumper_3_Bridged12 1: +5V; 2: Net-(J23-Pin_1); 3: +3V3
6AxisBreakout.kicad_pcb JP19 SolderJumper_3_Bridged12 1: +5V; 2: VS; 3: Net-(J24-Pin_2)
6AxisBreakout.kicad_pcb JP5 SolderJumper_3_Bridged12 1: +5V; 2: Net-(J18-Pin_1); 3: +3V3
6AxisBreakout.kicad_pcb JP13 SolderJumper_2_Bridged 1: Net-(J20-Pin_1); 2: Net-(JP13-B)
6AxisBreakout.kicad_pcb JP7 SolderJumper_3_Bridged12 1: +5V; 2: Net-(J20-Pin_1); 3: +3V3
6AxisBreakout.kicad_pcb JP11 SolderJumper_2_Bridged 1: Net-(J18-Pin_1); 2: Net-(JP11-B)
6AxisBreakout.kicad_pcb JP3 SolderJumper_3_Bridged12 1: +5V; 2: Net-(JP3-C); 3: +3V3
6AxisBreakout.kicad_pcb JP8 SolderJumper_3_Bridged12 1: +5V; 2: Net-(J21-Pin_1); 3: +3V3
6AxisBreakout.kicad_pcb JP4 SolderJumper_3_Bridged12 1: +5V; 2: Net-(JP4-C); 3: +3V3
6AxisBreakout.kicad_pcb JP9 SolderJumper_3_Bridged12 1: +5V; 2: Net-(J22-Pin_1); 3: +3V3
6AxisBreakout.kicad_pcb JP18 SolderJumper_2_Bridged 1: Net-(J6-Pin_1); 2: Net-(JP18-B)
6AxisBreakout.kicad_pcb JP6 SolderJumper_3_Bridged12 1: +5V; 2: Net-(J19-Pin_1); 3: +3V3

Practical use with Smoothieboard V2 Prime

Pending and unaccepted: no complete practical Prime → historical board → named peripheral drawing has been accepted. Unknown conductors remain unresolved rather than routed by guesswork.

For a retained retrofit study, first choose the exact external drivers and endstop circuits, then create a full signal allocation for all four actual Prime sockets. Keep power stages disabled while verifying every STEP/DIR/enable and endstop return through the selected buffers. Match UART, PWM timers and all power domains separately. GF/J37 supplies only seven GPIOs and cannot stand in for all four interfaces. External VS must not be connected until JP19 and host-backfeed behaviour are checked.

Conditional GF/J37 examples refer only to retained P12 Prime2590: contacts 1/2/10 are limited 3.3 V/limited 5 V/ground; contacts 3–9 are PB1/PJ4/PA4/PG0/PJ3/PG1/PJ2. The host header is unshrouded. Verify physical numbering, polarity, per-rail current allowance and free-pin ownership before connection. This pin map does not establish hardware SPI, UART, CAN or PWM availability on an arbitrary contact.

Smoothieware support and example boundary

Buffered A-min non-motion monitor and six-axis ownership

For the selected board distinguish raw A_MIN_IN at J18.3/J13.11 from buffered open-drain Amin at J2.7. JP5 source footprint Bridged12 selects raw pullup supply5 V; that is not an acceptable inference that J18.3 is a direct Prime input. A candidate buffered-output harness uses J2.7 to Prime GF/J37.3 PB1, J2.10 to GF.10 ground, after qualifying LCX07 input edge rate, output pullup and supply ordering. Use a separately qualified3.3 V output bias; the configuration below does not supply one.

[endstops]
buffered_amin_observation.enable = true
buffered_amin_observation.pin = PB1-
buffered_amin_observation.axis = X
buffered_amin_observation.homing_direction = none
buffered_amin_observation.limit_enable = false

An existing valid X actuator and exclusive pins are required. M119 reports the sampled logical state. The trailing minus disables internal pulls without inversion; supply a separately qualified external bias. No homing, limit or software-halt action is configured. Record both stable stimulus states and the disconnected/unpowered state with all machine motion disabled. This observation does not determine a safe fault polarity or provide debouncing/edge timing.

This is a useful single-input diagnostic and leaves all motors disconnected. It is not a six-axis configuration. Robot supports contiguous actuator names alpha/beta/gamma/delta/epsilon/zeta where the actual build supports them; this board’s J3/J4 channel order must be mapped independently. External drivers do not gain software slaving from a slaved_to label. Scaling, kinematics, shared enable and motor commands remain deliberately absent until the actual machine is named. For a required missing machine integration email wolf.arthur@gamil.com.

These instructions identify source behavior at SmoothieV2 commit 2a21c0108b1d095ecd8b2b9358e94055f053c003; they do not identify the installed build or prove target execution. Reserve every listed pin and command in the complete configuration. Merge entries into existing sections rather than duplicating sections. These software instructions do not verify powered hardware or provide a complete wiring diagram.

Remaining requirements

Four-socket mapping, complete buffered direction/polarity, six-axis firmware/kinematics, shared enable, endstop thresholds, VS selection and harness current remain unresolved. Both instructional diagrams, public source/link availability and desktop/narrow rendered usability remain open.

Sources and attribution

The retained inventory did not identify a project license file. Preserve attribution and resolve redistribution rights before importing original artwork/layouts; absence of a license file is not public-domain permission. Modern counterpart guides are functional comparisons only and do not establish matching pinouts.

All extension boards

This is a wiki! If you'd like to improve this page, you can edit it on GitHub.