Extruder toolhead harness without motor

This early passive harness prototype joins heater and fan positive supply while leaving separate low-side switched returns. It distributes thermistor, probe and servo connections without routing a motor. The upstream README explicitly marks it reference-only and not for production. It is not the modern extruder candidate and does not inherit that board’s ratings.

Documented revision and original host

This guide documents the historical Ccecil source snapshot, pinned by the local Smoothieboard2 parent, rather than a modern replacement board. The exact upstream revision identifies the retained design. A repository commit is not an assembly revision or evidence of current production. The original project is a custom 3D-printer harness; it has no ten-contact Prime plug-and-play host interface.

Interfaces, power and limitations

The Fusion archive contains original Eagle board/schematic XML. Named HOTEND, THERM, SERVO, FAN1, FAN2, PROBE connectors and VBB/H−/GND wire pads provide the actual endpoints; J2 is an eight-contact harness and JP1/JP2 select fan-related paths. Several nets are auto-generated N$ names, so the complete numbered source table below is essential. Shared positive is not ground, and the heater return must remain on the host’s switched power stage. No supply, heater current or copper-temperature rating is established.

Board-reference diagram

These source-matched sheets retain the historical artwork and identify its connectors, wire pads, selectors and indicators. The upstream design remains reference-only, not for production; DO NOT ENERGIZE from these sheets. It has no motor connection and no qualified supply, heater/fan current, thermal protection or Prime harness. Numbered source contacts are not a physical mating-face guarantee.

Historical toolhead harness without motor overview — historical reference-only harness source
Historical toolhead harness without motor overview Shared VBB positive and separate switched returns are source connectivity, not a qualified power installation. No motor connection exists. F1, F2 and H are LED device references, not fuses.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Historical toolhead harness without motor overview — historical reference-only harness source
Historical toolhead harness without motor overview
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Historical toolhead harness without motor overview — historical reference-only harness source

Harness and toolhead connectors

Eight-contact harness J2 · group 1 — historical reference-only harness source
Eight-contact harness J2 · group 1 Numbered source contacts only. Contact 6 has no assigned net and receives no invented connection. Auto-named nets must be traced to their source endpoints; the header is not a verified plug face.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Eight-contact harness J2 · group 1 — historical reference-only harness source
Eight-contact harness J2 · group 1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Eight-contact harness J2 · group 1 — historical reference-only harness source
Eight-contact harness J2 · group 2 — historical reference-only harness source
Eight-contact harness J2 · group 2 Numbered source contacts only. Contact 6 has no assigned net and receives no invented connection. Auto-named nets must be traced to their source endpoints; the header is not a verified plug face.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Eight-contact harness J2 · group 2 — historical reference-only harness source
Eight-contact harness J2 · group 2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Eight-contact harness J2 · group 2 — historical reference-only harness source
Heater connector HOTEND — historical reference-only harness source
Heater connector HOTEND Source contacts 1 VBB and 2 H−; contacts 3/4 have no assigned net. The connector value does not qualify current, voltage, copper heating or thermal protection.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Heater connector HOTEND — historical reference-only harness source
Heater connector HOTEND
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Heater connector HOTEND — historical reference-only harness source
Thermistor connector THERM — historical reference-only harness source
Thermistor connector THERM Two source contacts traced to J2.3/J2.5 nets. The retained native-pad overlay is a reference, not a sensor, ADC or cable qualification.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Thermistor connector THERM — historical reference-only harness source
Thermistor connector THERM
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Thermistor connector THERM — historical reference-only harness source
Servo connector SERVO — historical reference-only harness source
Servo connector SERVO Source contacts 1/2 map to J2.2/J2.1 nets and contact 3 to ground. Do not assume a conventional servo plug order, supply rating or supported servo.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Servo connector SERVO — historical reference-only harness source
Servo connector SERVO
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Servo connector SERVO — historical reference-only harness source
Probe connector PROBE — historical reference-only harness source
Probe connector PROBE Source contact 1 maps to J2.4 and 2 to ground. Sensor type, pull-up, voltage margins and firmware allocation remain unresolved.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Probe connector PROBE — historical reference-only harness source
Probe connector PROBE
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Probe connector PROBE — historical reference-only harness source
Fan connector FAN1 — historical reference-only harness source
Fan connector FAN1 Source contact 1 is the shared VBB net N$19; contact 2 is a switched/selector return. No fan voltage, current or host output stage is qualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Fan connector FAN1 — historical reference-only harness source
Fan connector FAN1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Fan connector FAN1 — historical reference-only harness source
Fan connector FAN2 — historical reference-only harness source
Fan connector FAN2 Source contact 1 is the shared VBB net N$19; contact 2 is a switched/selector return. No fan voltage, current or host output stage is qualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Fan connector FAN2 — historical reference-only harness source
Fan connector FAN2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Fan connector FAN2 — historical reference-only harness source

Rear fan-return selectors

Rear selector JP1 — historical reference-only harness source
Rear selector JP1 Native-source overlay for the three-pad rear selector. Ground, fan return and harness signal membership do not establish the fitted trace/bridge state, physical mating or safe powered population.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP1 — historical reference-only harness source
Rear selector JP1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP1 — historical reference-only harness source
Rear selector JP2 — historical reference-only harness source
Rear selector JP2 Native-source overlay for the three-pad rear selector. Ground, fan return and harness signal membership do not establish the fitted trace/bridge state, physical mating or safe powered population.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Rear selector JP2 — historical reference-only harness source
Rear selector JP2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Rear selector JP2 — historical reference-only harness source

Supply and switched-return wire pads

Shared positive VBB wire pad — historical reference-only harness source
Shared positive VBB wire pad Source wire-pad identity only. Shared positive is not ground; heater/fan returns belong to compatible switched power stages, not ordinary GPIO. Ampacity, polarity and host allocation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Shared positive VBB wire pad — historical reference-only harness source
Shared positive VBB wire pad
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Shared positive VBB wire pad — historical reference-only harness source
Heater switched-return H− wire pad — historical reference-only harness source
Heater switched-return H− wire pad Source wire-pad identity only. Shared positive is not ground; heater/fan returns belong to compatible switched power stages, not ordinary GPIO. Ampacity, polarity and host allocation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Heater switched-return H− wire pad — historical reference-only harness source
Heater switched-return H− wire pad
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Heater switched-return H− wire pad — historical reference-only harness source
Ground wire pad — historical reference-only harness source
Ground wire pad Source wire-pad identity only. Shared positive is not ground; heater/fan returns belong to compatible switched power stages, not ordinary GPIO. Ampacity, polarity and host allocation remain unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Ground wire pad — historical reference-only harness source
Ground wire pad
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Ground wire pad — historical reference-only harness source

LED indicators and series resistors

F1 fan indicator — historical reference-only harness source
F1 fan indicator This source device is an LED, not a fuse. Its anode is on VBB and its cathode feeds a series resistor. LED/resistor voltage, resistance, current and indication behavior are unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

F1 fan indicator — historical reference-only harness source
F1 fan indicator
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

F1 fan indicator — historical reference-only harness source
F2 fan indicator — historical reference-only harness source
F2 fan indicator This source device is an LED, not a fuse. Its anode is on VBB and its cathode feeds a series resistor. LED/resistor voltage, resistance, current and indication behavior are unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

F2 fan indicator — historical reference-only harness source
F2 fan indicator
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

F2 fan indicator — historical reference-only harness source
H heater indicator — historical reference-only harness source
H heater indicator This source device is an LED, not a fuse. Its anode is on VBB and its cathode feeds a series resistor. LED/resistor voltage, resistance, current and indication behavior are unqualified.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

H heater indicator — historical reference-only harness source
H heater indicator
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

H heater indicator — historical reference-only harness source
Indicator resistor R1 — historical reference-only harness source
Indicator resistor R1 Source series LED resistor; resistance is absent from the source. No safe LED current or supply recipe is inferred from its presence.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Indicator resistor R1 — historical reference-only harness source
Indicator resistor R1
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Indicator resistor R1 — historical reference-only harness source
Indicator resistor R2 — historical reference-only harness source
Indicator resistor R2 Source series LED resistor; resistance is absent from the source. No safe LED current or supply recipe is inferred from its presence.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Indicator resistor R2 — historical reference-only harness source
Indicator resistor R2
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Indicator resistor R2 — historical reference-only harness source
Indicator resistor R3 — historical reference-only harness source
Indicator resistor R3 Source series LED resistor; resistance is absent from the source. No safe LED current or supply recipe is inferred from its presence.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Indicator resistor R3 — historical reference-only harness source
Indicator resistor R3
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Indicator resistor R3 — historical reference-only harness source

Supplementary logical circuits

These independently drawn circuit sheets explain the selected source connectivity. They do not copy the original board artwork, placement or native files and supplement the source-matched board-reference sheets above. Use the contact inventory and all companion sheets together. Physical cable orientation, ratings, installed operation and the full Prime/peripheral wiring remain unverified.

Source: original Fusion archive, revision def3970de38643141e1a6176440cc079c666c853. The Eagle board data used here is extracted from that archive. No original-artwork redistribution grant has been established.

Hotend connector — logical connections, not physical board layout
Hotend connector Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Hotend connector — logical connections, not physical board layout
Hotend connector
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Hotend connector — logical connections, not physical board layout
Thermistor connector — logical connections, not physical board layout
Thermistor connector Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Thermistor connector — logical connections, not physical board layout
Thermistor connector
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Thermistor connector — logical connections, not physical board layout
Servo connector — logical connections, not physical board layout
Servo connector Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Servo connector — logical connections, not physical board layout
Servo connector
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Servo connector — logical connections, not physical board layout
Probe connector — logical connections, not physical board layout
Probe connector Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Probe connector — logical connections, not physical board layout
Probe connector
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Probe connector — logical connections, not physical board layout
Fan common supply — logical connections, not physical board layout
Fan common supply Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Fan common supply — logical connections, not physical board layout
Fan common supply
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Fan common supply — logical connections, not physical board layout
FAN2 return selection — logical connections, not physical board layout
FAN2 return selection Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

FAN2 return selection — logical connections, not physical board layout
FAN2 return selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

FAN2 return selection — logical connections, not physical board layout
FAN1 return selection — logical connections, not physical board layout
FAN1 return selection Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

FAN1 return selection — logical connections, not physical board layout
FAN1 return selection
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

FAN1 return selection — logical connections, not physical board layout
F1 indicator source connections — logical connections, not physical board layout
F1 indicator source connections Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

F1 indicator source connections — logical connections, not physical board layout
F1 indicator source connections
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

F1 indicator source connections — logical connections, not physical board layout
F2 indicator source connections — logical connections, not physical board layout
F2 indicator source connections Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

F2 indicator source connections — logical connections, not physical board layout
F2 indicator source connections
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

F2 indicator source connections — logical connections, not physical board layout
H indicator source connections — logical connections, not physical board layout
H indicator source connections Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

H indicator source connections — logical connections, not physical board layout
H indicator source connections
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

H indicator source connections — logical connections, not physical board layout
Unconnected native contact instances — logical connections, not physical board layout
Unconnected native contact instances Supplementary factual circuit only. The complete Prime installation remains incomplete. Connector locations, mating and assembled ratings are not established by this drawing.
Read labels at full size

Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.

Unconnected native contact instances — logical connections, not physical board layout
Unconnected native contact instances
Diagram size

Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.

Unconnected native contact instances — logical connections, not physical board layout

Numbered source contacts and controls

These are intended source net memberships, not measured electrical behaviour. Unassigned/unconnected pads must not receive invented connections. Auto-generated net names require schematic interpretation; they are not cable colours. Repeated footprints or pad numbers require geometric identity checks before wiring.

Selected-source contact inventory
Source member Connector/control Source label Contact → source net
SingleExtruder_noMotor.f3z HOTEND XT30PW-F 1: N$19; 2: N$12; 3: No assigned net; 4: No assigned net
SingleExtruder_noMotor.f3z THERM S2B-XH-A(LF)(SN) 1: N$11; 2: N$10
SingleExtruder_noMotor.f3z SERVO 22-23-2031 1: N$8; 2: N$7; 3: GND
SingleExtruder_noMotor.f3z FAN1 22-23-2021 1: N$19; 2: N$2
SingleExtruder_noMotor.f3z PROBE 22-23-2021 1: N$9; 2: GND
SingleExtruder_noMotor.f3z FAN2 22-23-2021 1: N$19; 2: N$1
SingleExtruder_noMotor.f3z JP1 JUMPER-SMT_3_1-NC_TRACE_NO-SILK 1: GND; 2: N$1; 3: N$6
SingleExtruder_noMotor.f3z JP2 JUMPER-SMT_3_1-NC_TRACE_NO-SILK 1: GND; 2: N$2; 3: N$5
SingleExtruder_noMotor.f3z J2 2X4 1: N$7; 2: N$8; 3: N$11; 4: N$9; 5: N$10; 6: No assigned net; 7: N$5; 8: N$6
SingleExtruder_noMotor.f3z VBB 3,81/1,4 1: N$19
SingleExtruder_noMotor.f3z H- 3,81/1,4 1: N$12
SingleExtruder_noMotor.f3z GND 2,54/1,0 1: GND
SingleExtruder_noMotor.f3z F2 CHIP-FLAT-R_0805 C: N$15; A: N$19
SingleExtruder_noMotor.f3z F1 CHIP-FLAT-R_0805 C: N$16; A: N$19
SingleExtruder_noMotor.f3z H CHIP-FLAT-R_0805 C: N$17; A: N$19

Practical use with Smoothieboard V2 Prime

Pending and unaccepted: no complete practical Prime → historical board → named peripheral drawing has been accepted. Unknown conductors remain unresolved rather than routed by guesswork.

For a harness continuity fixture, keep heater/fans disconnected and identify the VBB,H− and ground wire pads in the recovered board. Follow each J2 contact through the saved signal membership to its named load connector; do not infer functions from N$ numbering. Verify the chosen jumper population and cable mating orientation. A complete Prime harness needs separate heater/fan power outputs, thermistor input and compatible probe/servo pins, not one Gadgeteer cable. Do not energize this reference-only assembly from an assumed 12/24 V convention.

Conditional GF/J37 examples refer only to retained P12 Prime2590: contacts 1/2/10 are limited 3.3 V/limited 5 V/ground; contacts 3–9 are PB1/PJ4/PA4/PG0/PJ3/PG1/PJ2. The host header is unshrouded. Verify physical numbering, polarity, per-rail current allowance and free-pin ownership before connection. This pin map does not establish hardware SPI, UART, CAN or PWM availability on an arbitrary contact.

Smoothieware support and example boundary

The harness requires no driver. Its attached heater, sensor, fan and probe need independent compatible V2 modules and actual host allocations. No complete selected-source Prime configuration was verified.

The V2 implementation reviewed for this documentation is pinned to SmoothieV2 commit 2a21c0108b1d095ecd8b2b9358e94055f053c003. This does not identify the firmware installed on a reader’s controller or establish support for every historical board. Source-backed syntax is distinct from physical execution. If the required firmware functionality is absent, email wolf.arthur@gamil.com with the historical board, host revision and intended peripheral; unresolved support is not asserted to be absent.

Remaining requirements

Auto-named net semantics, fan jumper defaults, supply/current/cable limits, host allocation and source-reference-only production restriction remain unresolved. The complete Prime/peripheral wiring diagram remains incomplete. The board-reference sheets document source contacts without qualifying this reference-only prototype.

Sources and attribution

The retained inventory did not identify a project license file. Source attribution is retained for these locally prepared reference sheets. Absence of a license file is not public-domain permission; external redistribution rights remain unresolved. Modern counterpart guides are functional comparisons only and do not establish matching pinouts.

All extension boards

This is a wiki! If you'd like to improve this page, you can edit it on GitHub.