This passive board redistributes one V2 control header into three external-drive command connectors. It carries STEP, DIR and a shared ENABLE; it does not contain motor power stages and cannot drive motor windings directly. It is useful when connecting separately powered commercial drivers with compatible logic inputs.
This guide documents the historical Ccecil source snapshot, pinned by the local Smoothieboard2 parent, rather than a modern replacement board. The exact upstream revision identifies the retained design. A repository commit is not an assembly revision or evidence of current production. The source targets the Smoothieboard V2/Gadgeteer era. That intended generation does not prove compatibility with every later V2 Prime board, cable or firmware build.
J1 contacts 3–9 are DIR1,STEP1,STEP2,STEP3,DIR2,DIR3,ENABLE. J2/J3/J4 each use 1 selected +V, 2 STEP, 3 DIR, 4 shared ENABLE, 5 ground. JP1 centre +V selects host 5 V or 3.3 V. The selected rail supplies the external logic interface, not the motors; its current budget and the drive input topology must be checked. No isolation or universal optocoupler compatibility is implied.
JP1 selects the voltage distributed to the output supply contacts. STEP, DIR and ENABLE remain passive signal connections: selecting 5 V does not turn a Prime 3.3 V GPIO output into a 5 V signal.
For example, the Leadshine DM542E manual, printed page 3, specifies a 4.5–5 V logic HIGH in 5 V mode, a 0–0.5 V LOW, pulses of at least 2.5 µs and direction setup of at least 5 µs. Its factory 24 V input selection must be changed with S2 for 5 V operation. Direct 3.3 V GPIO drive does not meet that HIGH requirement. A complete example with this drive needs a specified buffer or sink circuit, including input-current, return-path and power-sequencing checks; JP1 alone cannot provide it. Other drives require their own interface review.
These source-matched reference sheets show the historical board’s actual artwork, connector contacts and supply selector. The highlighted locations refer to PCB geometry, not a cable mating face. Read the numbered contact sheets before choosing any connection. They do not qualify a powered installation.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
These independently drawn circuit sheets explain the selected source connectivity. They do not copy the original board artwork, placement or native files and supplement the source-matched board-reference sheets above. Use the contact inventory and all companion sheets together. Physical cable orientation, ratings, installed operation and the full Prime/peripheral wiring remain unverified.
Source: selected original circuit, revision 4f8760bac438c3a078ac421ea79f2562bbb123f2. No original-artwork redistribution grant has been established.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
Scroll across and down within this view. You can also open the PNG separately and use your browser’s zoom controls.
Fit shows the whole drawing. Zoom to read labels; scroll within the drawing. Escape closes the viewer.
These are intended source net memberships, not measured electrical behaviour. Unassigned/unconnected pads must not receive invented connections. Auto-generated net names require schematic interpretation; they are not cable colours. Repeated footprints or pad numbers require geometric identity checks before wiring.
| Source member | Connector/control | Source label | Contact → source net |
|---|---|---|---|
| StepXternal.kicad_pcb | J1 | Conn_02x05_Odd_Even | 1: +3V3; 2: +5V; 3: DIR1; 4: STP1; 5: STP2; 6: STP3; 7: DIR2; 8: DIR3; 9: EN; 10: GND |
| StepXternal.kicad_pcb | J2 | Conn_01x05_Male | 1: +V; 2: STP1; 3: DIR1; 4: EN; 5: GND |
| StepXternal.kicad_pcb | J4 | Conn_01x05_Male | 1: +V; 2: STP3; 3: DIR3; 4: EN; 5: GND |
| StepXternal.kicad_pcb | J3 | Conn_01x05_Male | 1: +V; 2: STP2; 3: DIR2; 4: EN; 5: GND |
| StepXternal.kicad_pcb | JP1 | SolderJumper_3_Bridged12 | 1: +5V; 2: +V; 3: +3V3 |
Pending and unaccepted: no complete practical Prime → historical board → named peripheral drawing has been accepted. Unknown conductors remain unresolved rather than routed by guesswork.
For one external stepper drive, select its exact logic interface and identify pulse/direction/enable polarities from its manual. Keep motor power disabled while mapping J2 to those inputs. A conditional GF/J37 allocation gives STEP1=J37.4 PJ4, DIR1=J37.3 PB1 and ENABLE=J37.9 PJ2, matching the board contact order rather than modern breakout assumptions. Select JP1 only after confirming rail compatibility and verify both enable states before any motor movement.
Conditional GF/J37 examples refer only to retained P12 Prime2590: contacts 1/2/10 are limited 3.3 V/limited 5 V/ground; contacts 3–9 are PB1/PJ4/PA4/PG0/PJ3/PG1/PJ2. The host header is unshrouded. Verify physical numbering, polarity, per-rail current allowance and free-pin ownership before connection. This pin map does not establish hardware SPI, UART, CAN or PWM availability on an arbitrary contact.
The passive breakout needs no device driver. This source-derived example uses channel 1 with a Pololu #2128 A4988 Black Edition carrier and a secured, unloaded 17HS19-2004S1 motor. It is a conditional diagnostic procedure, not a tested installation or a complete machine configuration. The required complete wiring illustration and physical mating checks remain open.
Use individually numbered leads; the breakout’s five-pin header does not mechanically match the carrier. With every supply off:
| Prime GF/J37 | Breakout input | Breakout output → carrier |
|---|---|---|
| 3 · PB1 | J1.3 DIR1 | J2.3 → DIR |
| 4 · PJ4 | J1.4 STP1 | J2.2 → STEP |
| 9 · PJ2 | J1.9 EN | J2.4 → EN |
| 10 · GND | J1.10 GND | J2.5 → logic GND |
Connect Prime GF/J37.1 limited 3.3 V separately to carrier VDD. Verify the host rail’s available current and fitted carrier load; the A4988 IC’s 8 mA maximum logic-supply characteristic is not a complete carrier or host power budget. Do not parallel another 3.3 V supply onto Prime. Leave GF/J37.2, breakout J1.1/.2, J2.1 and every J3/J4 output disconnected. JP1’s source footprint defaults to 1–2, selecting +5 V for unused +V; this example does not change that bridge or use that output rail.
On the carrier, connect RST and SLP to VDD, and MS1/MS2/MS3 to ground for full steps. Connect a separate 12 V motor supply only to VMOT and motor GND, with a common logic return. Follow Pololu’s local decoupling instructions, including at least 47 µF electrolytic close to VMOT/GND; independently check capacitor voltage rating, polarity and supply transients. Never put motor voltage on the breakout or Prime logic headers.
For an actual post-2017 carrier with verified 0.068 Ω sense resistors, an example 0.5 A trip limit requires VREF = 8 × 0.5 × 0.068 = 0.272 V. Set and measure it following the carrier instructions, with motor power off; older 0.050 Ω assemblies need a different calculation. Full-step winding current is approximately 70% of the trip setting. This reduced-current example does not promise rated torque or thermal qualification. Supply current is not coil current.
Connect carrier 1A/1B to the named motor’s Black/Green winding and 2A/2B to Red/Blue. Verify the actual winding pairs with power removed; never connect or disconnect motor leads while powered. The named motor has 1.8° full steps and a 2 A phase rating. Keep the shaft free of belts, screws, tools and loads.
Use an otherwise valid Prime configuration with alpha registered as X. Reserve these pins, merge entries into existing sections and remove conflicting owners. Disconnect all other actuators: M17 enables every configured motor. Alpha alone owns the shared enable line.
[actuator]
alpha.driver = external
alpha.step_pin = PJ4
alpha.dir_pin = PB1
alpha.en_pin = PJ2!
beta.en_pin = nc
gamma.en_pin = nc
These six settings do not program carrier current or microstep straps. The inverted enable drives physical LOW when enabled, as required by A4988. Host reset or loss of power does not guarantee a safe enable state. Keep motor power off during host startup and configuration; send M18 and verify EN HIGH before enabling the motor supply. After checking rails, current reference, polarity and windings, send M17, wait at least five seconds, then:
test pulse x 2
M18
At the pinned firmware revision, this diagnostic asserts STEP for five seconds, then deasserts it for five seconds, twice. It neither changes direction nor enables the motor itself. Two full steps request nominally 3.6° total, apart from initial rotor alignment; this is not measured motion or steps-per-millimetre calibration. Turn motor power off after M18; keep the host/common return connected until other supplies are off. Arbitrary hot-plugging and power order are not qualified.
The A4988 datasheet specifies 1 µs minimum STEP HIGH/LOW, 200 ns input setup/hold and logic thresholds of 0.7×VDD HIGH / 0.3×VDD LOW. Its input-current limits are ±20 µA under the stated tests. A common 3.3 V logic supply avoids the DM542E’s incompatible 5 V-mode HIGH requirement, but fitted Prime output margins, carrier loading, cabling, resets and fault handling still need verification.
Firmware behavior is checked against SmoothieV2 commit 2a21c0108b1d095ecd8b2b9358e94055f053c003: pulse diagnostic, motor enable commands and stepper initialization. This does not identify the installed build or prove target execution. For a required unsupported application or automatic fault/interlock feature, email wolf.arthur@gamil.com.
The named diagnostic closes the software example, not the full installation. The complete Prime/peripheral wiring diagram, connector mating, host power budget, reset/fault behavior, physical hardware, public links and actual desktop/narrow viewer acceptance remain open. The board-reference sheets document source geometry and contacts; they do not close these installation requirements.
The retained inventory did not identify a project license file. Source attribution is retained for these locally prepared reference sheets. Absence of a license file is not public-domain permission; external redistribution rights remain unresolved. Modern counterpart guides are functional comparisons only and do not establish matching pinouts.