Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Last revision Both sides next revision
temperaturecontrol-fine-tuning [2017/01/25 18:36]
arthur
temperaturecontrol-fine-tuning [2017/01/25 18:55]
arthur
Line 3: Line 3:
 you need to set max_pwm to 64 you need to set max_pwm to 64
  
-[[code]]+<code>
 temperature_control.hotend.max_pwm 64 # temperature_control.hotend.max_pwm 64 #
-[[/code]]+</code>
  
 ==== If you are getting 10°C or more  initial overshoot of temperature ==== If you are getting 10°C or more  initial overshoot of temperature
Line 11: Line 11:
 128 seems to be a good value, but it can be tuned with <​kbd>​M303 S0 Xnnn</​kbd>​ where nnn is a number <= max_pwm 128 seems to be a good value, but it can be tuned with <​kbd>​M303 S0 Xnnn</​kbd>​ where nnn is a number <= max_pwm
  
-[[code]]+<code>
 temperature_control.hotend.i_max 128 # temperature_control.hotend.i_max 128 #
-[[/code]]+</code>
  
 ==== To avoid accidental setting of too high a temperature ==== To avoid accidental setting of too high a temperature
Line 21: Line 21:
 It will also shutdown if this temperature is exceeded. It will also shutdown if this temperature is exceeded.
  
-[[code]]+<code>
 temperature_control.hotend.max_temp 230    # temperature_control.hotend.max_temp 230    #
-[[/code]]+</code>