smoothieware-website-v1

Parameter Default Description
extruder.module_name.enable true Whether to activate the extruder module at all. All configuration is ignored if false. Each time an extruder.module_name.enable line is encountered, an extruder module with the name «module_name» will be created.
extruder.module_name.steps_per_mm 140 Steps/millimetre for the extruder stepper motor. This is the number of steps to move one millimetre of filament. Learn more
extruder.module_name.filament_diameter 1.74 Filament diameter, in millimetres, used for volumetric extrusion control. Learn more
extruder.module_name.default_feed_rate 600 Default rate in millimetres/minute for moves where only the extruder moves. This is only used if you have never provided a feedrate via the F parameter. Once you specify a F parameter, it will be used as the Extruder feed rate until you reset the board.
extruder.module_name.acceleration 500 Acceleration for the extruder stepper motor, in millimetres/second/second
extruder.module_name.max_speed 50 Maximum allowable speed for the extruder stepper motor, in millimetres/second
extruder.module_name.step_pin 2.3 Pin for extruder stepper motor driver’s step signal
extruder.module_name.dir_pin 0.22 Pin for extruder stepper motor driver’s direction signal
extruder.module_name.en_pin 0.21 Pin for extruder stepper motor driver’s enable signal
extruder.module_name.x_offset 0 Extruder offset from origin in millimetres for the X axis. ONLY used when you have multiple extruders to specify the offset from each extruder to the first one.
extruder.module_name.y_offset 0 Extruder offset from origin in millimetres for the Y axis. ONLY used for multiple extruders
extruder.module_name.z_offset 0 Extruder offset from origin in millimetres for the Z axis. ONLY used for multiple extruders
extruder.module_name.retract_length 3 Retract length in millimetres. Retract is a retractation of the filament called using the G10 G-code. It is recovered (reverted) using the G11 G-code. Learn more about retractation
extruder.module_name.retract_feedrate 45 Retract feed-rate (filament speed) in millimetres/second
extruder.module_name.retract_recover_length 0 Additional length when recovering (if you retract by 1mm, you will be recovering by 1mm plus this value)
extruder.module_name.retract_recover_feedrate 8 Recovery feed-rate in millimetres/second (should be less than retract feedrate)
extruder.module_name.retract_zlift_length 0 Z-lift on retract in millimeters, set to 0 if you want to disable retraction Z-lift. Z-lift is a small increase in the Z axis position when retracting.
extruder.module_name.retract_zlift_feedrate 6000 Z-lift feed-rate in millimetres/minute (Note: mm/min NOT mm/sec)
delta_current 1.5 First extruder stepper motor driver (M4) current in Amperes
epsilon_current 1.5 Second extruder stepper motor driver (M5) current in Amperes