The following are the configuration options for the Delta Grid leveling strategy:
Option | Value | Description |
---|---|---|
leveling-strategy.delta-grid.enable |
true |
The strategy must be enabled in the config, as well as the zprobe module. |
leveling-strategy.delta-grid.size |
7 |
The size of the grid, for example, 7 causes a 7x7 grid with 49 points. Must be an odd number. |
leveling-strategy.delta-grid.probe_offsets |
0,0,0 |
Optional probe offsets from the nozzle or tool head. NOTE: Z must be 0 |
leveling-strategy.delta-grid.save |
false |
If the saved grid is to be loaded on boot then this must be set to true. |
leveling-strategy.delta-grid.initial_height |
10 |
Optionally, an initial_height can be set that tells the initial probe where to stop the fast descent before it probes. This should be around 5-10mm above the bed. |