delta-calibration-strategy-options [2017/01/25 14:19] (current) arthur created |
||
---|---|---|---|
Line 1: | Line 1: | ||
+ | || leveling-strategy.delta-calibration.enable || true || Set to true to enable the delta calibration levelling strategy. This uses the probe to figure out the plane's tilt and arm's radius in a delta machine || | ||
+ | || leveling-strategy.delta-calibration.radius || 100 || Radius at which to probe the three points || | ||
+ | || leveling-strategy.delta-calibration.initial_height || 10 || the initial height above the bed we stop the initial move down after home to find the bed. This should be a height that is enough that the probe will not hit the bed and is an offset from gamma_max (can be set to 0 if gamma_max takes into account the probe offset) || |