temperaturecontrol-thermistor-choice [2017/01/25 23:03]
arthur
temperaturecontrol-thermistor-choice [2018/11/02 18:29] (current)
75.108.123.165 Workaround for lack of kbd escape, update the most recent keyboard dokuwiki plugin to use escapes for better appearance
Line 9: Line 9:
 Smoothie does not know the name of all the thermistors in existence. At the moment these are the ones it knows about: Smoothie does not know the name of all the thermistors in existence. At the moment these are the ones it knows about:
  
-^ Name ^ Beta for 0-80°C ​^ Beta for 185-230°C ​^ I for Steinhart Hart ^ J for Steinhart Hart ^ K for Steinhart Hart ^ Part number ^ +^ Name ^ Beta for 0-80°C ^ Beta for 185-230°C ​^ I for Steinhart Hart ^ J for Steinhart Hart ^ K for Steinhart Hart ^ Part number ^ 
-|| <​kbd>​EPCOS100K</​kbd> ​|| 4066 || 4193 || 0.000722378300319346F ​|| 0.000216301852054578F ​|| 9.2641025635702e-08F ​|| B57540G0104F000 ​|+| <​kbd>​EPCOS100K</​kbd>​ | 4066 | 4193 | 0.000722378300319346F | 0.000216301852054578F | 9.2641025635702e-08F | B57540G0104F000 | 
-|| <​kbd>​Honeywell100K</​kbd> ​|| 3974 || 4385 || 0.000596153185928425F ​|| 0.000231333192738335F ​|| 6.19534004306738e-08F ​|| 135-104LAG-J01 ​|+| <​kbd>​Honeywell100K</​kbd>​ | 3974 | 4385 | 0.000596153185928425F | 0.000231333192738335F | 6.19534004306738e-08F | 135-104LAG-J01 | 
-|| <​kbd>​Semitec</​kbd> ​|| 4267 || 4375 || 0.000811290160145459F ​|| 0.000211355789144265F ​|| 7.17614730463848e-08F ​|| 104GT-2 ​|+| <​kbd>​Semitec</​kbd>​ | 4267 | 4375 | 0.000811290160145459F | 0.000211355789144265F | 7.17614730463848e-08F | 104GT-2 | 
-|| <​kbd>​Honeywell-QAD</​kbd> ​|| || || 0.000827339299500986F ​|| 0.000208786427208899F ​|| 8.05595282332277e-08F ​|| 135-104QAD-J01 ​|+| <​kbd>​Honeywell</​kbd><​kbd>​-</​kbd><​kbd>​QAD</​kbd>​ ||| 0.000827339299500986F | 0.000208786427208899F | 8.05595282332277e-08F | 135-104QAD-J01 | 
-|| <​kbd>​Semitec-104NT4</​kbd> ​|| || || 0.000797110609710217F ​|| 0.000213433144381270F ​||6.5338987554e-08F ​|| 104NT-4R025H42G ​|+| <​kbd>​Semitec</​kbd><​kbd>​-</​kbd><​kbd>​104NT4</​kbd>​ ||| 0.000797110609710217F | 0.000213433144381270F | 6.5338987554e-08F | 104NT-4R025H42G | 
-|| <​kbd>​RRRF100K</​kbd> ​|| 3960 ||  || ||  ||  ||  ​|| +| <​kbd>​RRRF100K</​kbd>​ | 3960 |||||| 
-|| <​kbd>​RRRF10K</​kbd> ​|| 3964 ||  ||  ​|| ​ ||  ||  ​|| +| <​kbd>​RRRF10K</​kbd>​ | 3964 |||||| 
-|| <​kbd>​HT100K</​kbd> ​|| 3990 ||  ​|| ​ ||  ||  ​||  ||+| <​kbd>​HT100K</​kbd>​ | 3990 ||||||
  
 **In case you have a thermistor that is not known to Smoothie** you can simply define the parameters in config. There are two methods, using the beta value ( good but not perfect ), and using the Steinhart Hart algorythm ( perfect ). **In case you have a thermistor that is not known to Smoothie** you can simply define the parameters in config. There are two methods, using the beta value ( good but not perfect ), and using the Steinhart Hart algorythm ( perfect ).
Line 30: Line 30:
  
 <callout type="​warning"​ icon="​true"​ title="​ About beta values">​ <callout type="​warning"​ icon="​true"​ title="​ About beta values">​
-The betas published by most manufacturers,​ are for the 0-80°C ​range.+The betas published by most manufacturers,​ are for the 0-80°C range.
  
-For the 185-230°C ​this results in readings being about 7-10°C ​too high.+For the 185-230°C ​this results in readings being about 7-10°C too high.
  
 This means beta values are usually good for a heated bed, but not for a hotend. This means beta values are usually good for a heated bed, but not for a hotend.
 </​callout>​ </​callout>​
  
-If the thermistor is 100K ohms at 25°C ​then this is usually enough.+If the thermistor is 100K ohms at 25°C then this is usually enough.
  
 You can also set r0,t0,r1,r2 but this is not usually needed as the defaults are sufficient. You can also set r0,t0,r1,r2 but this is not usually needed as the defaults are sufficient.
  
-If you do not know what thermistor model you have, contact the designer or seller of your 3D printer, hotend or heated bed and get the spec which will tell you what the beta value is for the thermistor.+If you do not know what thermistor model you have, contact the designer or seller of your 3D printer, hotend or heated bed and get the spec which will tell you what the beta value is for the thermistor.
  
 **Using the Steinhart Hart algorythm :** **Using the Steinhart Hart algorythm :**
  
-This is the recommended method. Set the parameters in the configuration file : +This is the recommended method. Set the parameters in the configuration file :
  
 <​code>​ <​code>​