temperaturecontrol-pid-autotuning [2017/01/25 18:55]
arthur
temperaturecontrol-pid-autotuning [2017/02/27 05:30]
73.181.225.35
Line 7: Line 7:
 </​code>​ </​code>​
  
-* E**0** is the number of the temperaturecontrol ​module, ​in the order they have been configured. Here it would be 0 for the hotend, and 1 for the bed.+* E**0** is the number of the heater or bed temperature control ​module, ​determined by the order that they appear in the config file. Here it would be 0 for the hotend, and 1 for the bed.
 * S**190** is the temperature to autotune for. Use the temperature you will be using your heater at in real life. For a hotend here we use 190c * S**190** is the temperature to autotune for. Use the temperature you will be using your heater at in real life. For a hotend here we use 190c
  
Line 50: Line 50:
 <callout type="​warning"​ icon="​true"​ title="​ Network">​ <callout type="​warning"​ icon="​true"​ title="​ Network">​
  
-Do not send M303 over ​the web interface, use Telnet, Pronterface or any other serial terminal. If sent over the web, the answers will accumulate in Smoothie'​s RAM and may crash it.+Do not send <​key>​M303</​key>​ over ​the web interface, use Telnet, Pronterface or any other serial terminal. If sent over the web, the answers will accumulate in Smoothie'​s RAM and may crash it.
  
 </​callout>​ </​callout>​