Line 23: Line 23:
 || temperature_control.[[module_name]].max_temp || 100 || If set, no temperature above this will be accepted and if the temperature exceeds this value the system will be forced into a HALT state. || || temperature_control.[[module_name]].max_temp || 100 || If set, no temperature above this will be accepted and if the temperature exceeds this value the system will be forced into a HALT state. ||
 || temperature_control.[[module_name]].runaway_heating_timeout || 120 || If we take longer than this many seconds to heatup, the system will be forced into a HALT state. Set to 0 to disable it. default is 900 seconds|| || temperature_control.[[module_name]].runaway_heating_timeout || 120 || If we take longer than this many seconds to heatup, the system will be forced into a HALT state. Set to 0 to disable it. default is 900 seconds||
 +|| temperature_control.[[module_name]].runaway_cooling_timeout || 120 || If we take longer than this many seconds to cooldown, the system will be forced into a HALT state. Set to 0 to disable it. default is disabled||
 || temperature_control.[[module_name]].runaway_range || 20 || If set to non-zero, and the target temperature is reached, and temperature diverges from the target temperature by more than this, the system will be forced into a HALT state. || || temperature_control.[[module_name]].runaway_range || 20 || If set to non-zero, and the target temperature is reached, and temperature diverges from the target temperature by more than this, the system will be forced into a HALT state. ||