Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
steinharthart [2017/01/25 18:36]
arthur
steinharthart [2017/12/07 12:34]
178.202.190.149 correct misspelling
Line 3: Line 3:
 This can be done by adding this to the configuration : This can be done by adding this to the configuration :
  
-[[code]]+<code>
 temperature_control.hotend.rt_curve ​         20.0,​126800,​150,​1360,​240,​206.5 temperature_control.hotend.rt_curve ​         20.0,​126800,​150,​1360,​240,​206.5
-[[/code]]+</code>
  
 Where the 6 numbers are temperature/​resistance pairs for three sets of readings. ​ Where the 6 numbers are temperature/​resistance pairs for three sets of readings. ​
Line 19: Line 19:
 At a command prompt (or in [[pronterface]] prefix with @) type :  At a command prompt (or in [[pronterface]] prefix with @) type : 
  
-[[code]]+<code>
 calc_thermistor 25,​100000.0,​150,​1655.0,​240,​269.0 calc_thermistor 25,​100000.0,​150,​1655.0,​240,​269.0
-[[/code]]+</code>
  
 When you issue this command you get an answer like : When you issue this command you get an answer like :
  
-[[code]]+<code>
 Steinhart Hart coefficients: ​ I0.000722376862540841 J0.000216302098124288 K0.000000092640163984 Steinhart Hart coefficients: ​ I0.000722376862540841 J0.000216302098124288 K0.000000092640163984
   Paste the above in the M305 S0 command, then save with M500   Paste the above in the M305 S0 command, then save with M500
-[[/code]]+</code>
  
 So either issue the command... So either issue the command...
Line 38: Line 38:
 Or enter them in the config :  Or enter them in the config : 
  
-[[code]]+<code>
 temperature_control.hotend.coefficients 0.000722376862540841,​0.000216302098124288,​0.000000092640163984 temperature_control.hotend.coefficients 0.000722376862540841,​0.000216302098124288,​0.000000092640163984
-[[/code]]+</code>
  
-Another ​alrternative ​is to issue the command:+Another ​alternative ​is to issue the command:
  
-[[code]]+<code>
 calc_thermistor -s0 25,​100000.0,​150,​1655.0,​240,​269.0 calc_thermistor -s0 25,​100000.0,​150,​1655.0,​240,​269.0
-[[/code]]+</code>
  
 This will set the specified thermistor (0 is hotend) to the calculated values, this can then be saved with <​kbd>​M500</​kbd>​. This will set the specified thermistor (0 is hotend) to the calculated values, this can then be saved with <​kbd>​M500</​kbd>​.
Line 63: Line 63:
 You can force smoothie to continue to use the old beta settings for all predefined thermistors by setting :  You can force smoothie to continue to use the old beta settings for all predefined thermistors by setting : 
  
-[[code]]+<code>
 temperature_control.hotend.use_beta_table ​ true    # force predefined thermistotres to use the old beta values temperature_control.hotend.use_beta_table ​ true    # force predefined thermistotres to use the old beta values
-[[/code]]+</code>